Abstract
Nowadays powerful X-ray sources like synchrotrons and free-electron lasers are considered as ultimate tools for probing microscopic properties in materials. However, the correct interpretation of such experiments requires a good understanding on how the beam affects the properties of the sample, knowledge that is currently lacking for intense X-rays. Here we use X-ray photon correlation spectroscopy to probe static and dynamic properties of oxide and metallic glasses. We find that although the structure does not depend on the flux, strong fluxes do induce a non-trivial microscopic motion in oxide glasses, whereas no such dependence is found for metallic glasses. These results show that high fluxes can alter dynamical properties in hard materials, an effect that needs to be considered in the analysis of X-ray data but which also gives novel possibilities to study materials properties since the beam can not only be used to probe the dynamics but also to pump it.
Similar content being viewed by others
Introduction
Usually the interaction between X-rays and matter is weak and therefore they are an excellent probe to study the properties of materials1. However, the tremendous increase in brilliance of modern X-ray sources such as third-generation synchrotrons and free-electron lasers allows now to use photon fluxes that are so high that one cannot assume any more that the probe beam does not affect the properties of the sample. It is therefore important to obtain a solid understanding on how this strong flux influences the measurements since only this knowledge will allow a correct interpretation of the obtained results.
As it has been documented before, X-rays can in fact induce chemical rearrangements in soft materials like polymers and biological samples2. Here the ionizing action of the radiation can modify the structure of the system and even result in its complete disruption. In these cases two main processes have been identified3, 4. A first primary damage occurs on femtosecond timescales, and is related to the creation of free radicals by photoelectric absorption and Compton scattering3. The diffusion of these radicals can then lead to a secondary damage through the formation of additional radicals and the breaking of chemical bonds. As this second process occurs on a timescale of microseconds to milliseconds at room temperature, it can be largely suppressed by working at cryogenic temperatures5. Although it is impossible to completely remove the radiation damage, studies on protein crystallography show that it is nevertheless possible to get unique intrinsic properties of a given system6,7,8. For the case of soft materials the radiation damage can limit the achievable resolution9. However, this problem can be considerably alleviated by means of fast single shot exposure at high brilliance and fast X-ray sources as free-electron lasers10, 11.
In hard condensed matter X-rays can affect the system through three main mechanisms: Radiolysis, knock-on events and electron rearrangements12, 13. The first process occurs under UV and X-rays irradiation and leads to the formation of electron-hole pairs and atomic rearrangements. The second effect manifests itself via the displacements of atoms by collision processes that lead to the formation of vacancy-interstitial pairs, such as Frenkel defects13. This process usually requires energies as high as 100 keV in order to break atomic bonds in the irradiated materials. The third process are electron rearrangements which occur in presence of pre-existing (natural or induced) defects that serve as electron and hole trap.
Recently Leitner et al. investigated for the first time the interaction between hard X-rays and crystalline materials by looking directly at its consequence on the atomic diffusion14. That study was done by using X-ray Photon Correlation Spectroscopy (XPCS)15, a technique which has emerged as a powerful tool to probe the atomic motion in hard crystalline16 and amorphous materials17. By collecting series of diffuse scattering patterns with coherent X-rays, XPCS measures the atomic motion through the temporal intensity fluctuations of the speckles generated by the interference of the waves scattered by the atoms in the material. The detailed analysis of Leitner and co-workers shows that the radiation impinging on crystalline alloys can be treated in the linear response regime, i.e. the perturbation due to the beam is negligible14.
Here we show that things change completely for the case of simple oxide glasses such as vitreous silica and germania, where the X-rays generate a non-trivial stationary dynamics. In strong contrast to this behaviour, we find that the intrinsic dynamics of metallic glasses is not affected by the X-rays as in crystalline alloys14. Differences in electronic properties and the way electronic excitations couple to phonons are probably the reason for the different behaviour of these two classes of amorphous materials.
This unexpected interaction of the X-rays with hard materials has so far been totally neglected in the interpretation of X-ray data and resembles the one recently observed with transmission electron microscopy18. This suggests that X-rays can be also used as a novel type of pump and probe experiment, allowing to get physical properties of materials which cannot be achieved by means of any other technique.
Results
The effect of hard X-rays on the atomic motion of a given material can be studied by comparing dynamical measurements taken for different sample positions and incoming intensities selected by inserting X-ray attenuators along the beam path. Each attenuator is made of a polished silicon single crystal and leads to a decrease of the X-ray flux, F, by a factor ≈1/e at 8.1 keV. We have measured the dynamics with no attenuators (F 0 ≈ 1 · 1011 ph/s) and with filters of different thickness: ≈80 μm thick (F 1≈3 · 1010 ph/s), ≈160 μm thick (F 2 ≈ 1.2 · 1010 ph/s), and ≈240 μm thick (F 3 ≈ 3.6 · 109 ph/s).
Figure 1a shows the normalized intensity autocorrelation function g2(Q,t) of SiO2 at T = 295 K and for a wave-vector Qp = 1.5 Å−1 corresponding to the position of the maximum in the structure factor. The function g2(Q, t) is directly related to the density fluctuations in the material and thus provides information on its relaxation dynamics15. Lines in the figure are fits using the Kohlrausch-Williams-Watts (KWW) function g2(Q, t) = 1 + c · exp(−2(t/τ)β), where c contains information on the experimental contrast and the nonergodicity factor of the glass, β describes the shape of the curve, and τ is the characteristic decay time15.
Surprisingly the correlation functions of vitreous silica display a full decorrelation to zero, even at ambient temperature, thus a temperature that is only 20% of the glass transition temperature Tg, in agreement with previous results for silicate glasses19, 20. However, in marked contrast with these previous studies, the decorrelation on the atomic scale observed here cannot be ascribed to spontaneous density fluctuations as it depends strongly on the incident flux of the sample in that the decay shifts toward longer times upon decreasing F. Since the decay time increases by about two orders of magnitude when the flux is decreased by the same amount we expect that τ is inversely proportional to F. This is confirmed by the presence of a master curve in Fig. 1b where we show the same data as in panel (a), but now as a function of the time normalized to the flux. Similar results have been obtained also for GeO2 (see Fig. S1), while this effect is absent in metallic glasses (Fig. 1c), in agreement with the work of Leitner and coworkers14. As discussed below, the marked difference in the atomic motion of oxide and metallic glasses can be attributed to the different manner how metals and insulators react on the atomic scale to the deposit of the energy carried by the X-rays and the concomitant real occurrence of microscopic structural rearrangements in metallic glasses, as confirmed also by several X-ray diffraction studies21,22,23.
The observed dependence of the relaxation dynamics on the incident flux suggests that in the absence of such a flux silica glass is in an arrested state, with relaxation times likely too large to be observed during the experimental time scale considered here. We have tested this hypothesis with a set of measurements that had a constant lagtime, Δt = 6.15 s, between two consecutive images. This time is the sum of the exposure time Δt e (beam on), the sleeping time Δt s (beam off), and the readout time Δt r = 1.15 s (beam off), i.e. Δt = Δt e + Δt s + Δt r . Figure 2a clearly shows that the measured decay time τ, increases as we reduce the exposure time. This process follows approximately the relationship: \(\tau ={\tau }_{0}\frac{{\rm{\Delta }}t}{\Delta {t}_{e}}\), where τ 0 is the decay time for continuous exposure and negligible readout time (Δt s = Δt r = 0). For example, g2(Q, t) measured with a continuous exposure of Δt e = 5 s per frame (red symbols) is approximately one order of magnitude faster than that obtained by using Δt e = 0.5 s and a sleeping time Δt s = 4.5 s between frames (purple symbols). This result gives thus evidence that during the sleeping time the sample does not relax on the atomic scale, at least on the scale of 2-3 hours and at the room temperature considered here. As a consequence the measured decay time can thus be expected to be completely controlled by the mean photon flux impinging on the sample between two frames. To test this we plot in Fig. 2b the g2(Q, t) of Fig. 2a as a function of the mean flux \( < F > ={F}_{0}\frac{{\rm{\Delta }}{t}_{e}}{{\rm{\Delta }}t}\). The almost perfect overlap of the three curves clearly demonstrates that the measured dynamics is indeed triggered by the X-ray beam acting both as a pump and a probe. Another way to see this is to keep the exposure time fixed and to vary the sleeping time (Fig. 2c). We recognize that the duration of the sleeping time does not affect the relaxation time of the system, thus showing that the latter depends only on the mean flux onto the sample (see Fig. S2 for the same scaling for GeO2).
The results we just discussed imply that the relaxation time τ of the system is inversely proportional to the mean flux <F>, and thus can be changed basically at will. This is shown in Fig. 2d where we plot τ for a large set of data taken with different parameters (exposure times, sleeping times, and incident intensities) as a function of the mean flux received by the sample in each frame. Also included is data taken in a second SiO2 sample and in GeO2. It is clear that τ depends linearly on the inverse of the X-ray flux impinging the sample, suggesting a very slow dynamics in absence of X-rays, at least in these two simple oxide glasses. This result is in agreement with the work of Welch et al. who reported for similar systems a relaxation time of about ~27 d at ambient temperature24.
The effect discussed here cannot be classified as standard radiation damage since the induced dynamics is independent on the accumulated dose deposited on a particular sample position (see S.I.). Furthermore, we have found that the decay time can be reversibly modified by simply changing the intensity of the beam. This is demonstrated in Fig. 3a that shows the two-time correlation function (TTCF) measured in SiO2 while changing the beam attenuation without stopping the measurement. As explained in ref. 25, each point of the TTCF corresponds to the product of two images acquired at two different times. The effect of the different attenuators is signalled by the abrupt changes in the TTCF profile along the main diagonal whose width is proportional to the decay time of g2(Q, t). The higher the incoming intensity, the faster is the dynamics and thus the thinner is the intensity broadening along the diagonal. Interestingly, the decay time changes quickly (in less than one frame, thus ≈6 s) as we insert the corresponding attenuator during data acquisition. In addition, for a fixed incoming intensity the profile of the TTCF remains constant with time thus implying that the corresponding dynamics is stationary and does not depend on the total accumulated dose. By averaging the set of images corresponding to each attenuator we obtain five g2(Q,t) whose decay times and shape parameters are reported in Fig. 3b and c. While τ jumps in a reversible way between the values associated with each flux, β remains constant with β = 1.38 ± 0.09, which strongly differs from the stretched exponential decay (i.e. with β < 1) observed in silicates19, 20. Similar compressed decays (i.e. with β > 1) have been reported for soft materials and metallic glasses and they could be associated to a strain field in the material generated by a random distribution of slowly-evolving sources of internal stresses26, 27.
In view of the presented results one might wonder whether the same X-ray induced dynamics occurs also in previously measured silicates19, 20. Unfortunately, insufficient statistics does not allow to perform the same test as in SiO2. Even if present, the observed effect can be expected to disappear at high temperatures as the relaxation times measured in the glass transition region of sodium tetrasilicate glass (NS4) gently decrease with increasing temperatures and are found to match macroscopic measurements in the supercooled liquid19. It is important to note that despite the flux dependence of the relaxation time, the measured dynamics still provides physical information on the probed material. The shape of the correlation functions is compressed in the two simple oxide glasses and in the metallic glass investigated here while stretched in silicates, hence independently of whether the dynamics is induced by the X-ray beam or not.
The distinct nature of the probed atomic motion in silica and silicates leads also to a different dependence of the decay time on the wave-vector Q. For SiO2 and GeO2, τ continuously decreases on increasing Q (Fig. 4 for SiO2 and Fig. S3 for GeO2), whereas it displays an oscillatory behaviour in NS419 and in the lead silicates studied by Ross and coworkers20. It is important to stress that the incident flux impinging on the samples is the same for both glasses (SiO2 and NS4) and all wave-vectors. Therefore, the intensity cannot be responsible for the observed differences that should instead be ascribed to the details of the local atomic surroundings. Indeed, at low Qs τ(Q) displays the typical increases observed in other glass-formers liquids28, 29. What is remarkable, however, is the fact that the flux influences the Q-dependence of τ only via a Q-independent multiplicative factor, see Fig. 4. This indicates that the resulting observed dynamics can still be used to probe the Q-dependence of the real dynamics.
Discussions
The intriguing findings described above suggest the existence of a surprising system-dependent material-radiation interaction which can completely alter the outcome of an experiment and great care should be taken when analyzing X-ray data. In the case of in vitreous SiO2 and GeO2, the interaction with X-rays leads to a dynamic process whose main features can be summarized as follows:
-
i)
The incident X-ray flux induces an atomic motion at temperatures well below Tg. The time scale for this motion is inversely proportional to the photon flux. No decorrelation is observed if the system is not irradiated (at least on the scale of hours).
-
ii)
At fixed flux, the dynamics remains stationary and is independent of the accumulated dose.
-
iii)
The decay time depends in a reversible way and almost instantaneously on the incident flux.
-
iv)
The shape of the correlation functions is independent of the flux and should therefore reflect an intrinsic property of the glass.
-
v)
The flux does not affect the wave-vector dependence of the decay time at least for intermediate and small Qs.
-
vi)
The described induced dynamics is observed for simple oxide glasses. Different glasses display distinct behaviours, in that, for instance, metallic glasses are not affected by the X-rays.
The above observations point to a complex beam-activated process which differs from the classical radiation damage reported in XPCS studies on soft materials30, 31. In these cases, the dynamics clearly varies with the global dose, resulting often in pronounced aging phenomena that are usually triggered by significant structural damage, although there are cases where clear structural changes seem to be absent. The latter situation seems to imply the existence of a threshold for radiation damage that is lower for dynamical studies than the one for structural investigations, in agreement with recent studies of protein diffusion32.
In our work, the probed glasses show only a weak, almost negligible, structural change within the global irradiation dose used for the measurements (less than ≈104 s at F0), see Supplemental Information, while we do observe remarkable modifications for larger accumulated dose. For this large dose the X-rays modify the average local structure leading to a decrease of the intensity of the maximum in the static profile and a concomitant increase at ≈0.9 Å−1 (see Figs S4 and S5). Despite the occurrence of strong radiation damage at larger accumulated doses, we do not associate the observed dynamics to that damage: If it were the case, the dynamics would evolve with the accumulated dose (and thus the decay time as well) and would not be reversible when the flux is changed (see also Figs S6 and S7 for further confirmation).
Instead we believe that the effect reported in this work is likely due to radiolysis. Here the interaction with the X-rays generates localized electronic excitations with energies well below those necessary for knock-on events but large enough for atomic displacements4, 33. In order to convert these excitations into a mechanical response, they should have a lifetime of ≈1 ps and couple to the phonons. The details of these interactions are most probably system specific and thus would require additional computational modeling and experimental studies which go behind the purpose of this work. Metallic glasses do not show the discovered dependence on the flux since their electronic excitations delocalize faster, i.e. on the fs timescale. In alloys the atomic motion can be induced only through a direct transfer of momentum and energy by knock-on processes which require energies much higher than those employed here12, 17. In addition we point out that the glassy state of amorphous alloys cannot be considered arrested as in oxide glasses: It is indeed well known from diffraction studies that metallic glasses display structural atomic changes well below the glass transition temperature21,22,23. In this case XPCS directly probes the effect of these changes on the atomic motion21 which can lead to very complex dynamical patterns under the same irradiated conditions 34, 35. We do expect, however, that the flux induced dynamics found in the present work is likely to occur also in other non-conducting systems like polymeric compounds and molecular glasses, i.e. that this is a phenomenon that is not just a particularity of the simple oxide glasses considered here.
The induced dynamics in the simple oxide glasses strongly resembles the one observed in electron transmission microscopy18 and hints that the X-rays should not only be considered as a spectator but also as an important actor in the probed dynamics. Depending on the competition between the intrinsic and the induced dynamics, this effect can certainly become an issue for the determination of the associated time scales, as in the case presented here. However, one should keep in mind that it can be also considered as a novel type of pump and probe experiment that gives the great opportunity to probe physical properties of materials which cannot be achieved by means of any other technique.
Finally, it is worth highlighting that these beam-induced effects will become increasingly relevant for experiments at next generation synchrotrons36, 37 and at free-electron lasers sources38. In the latter case, techniques using high intense coherent beams, such as XPCS, are based on fs pulses that have intensities as high as current synchrotron sources provide in one second39,40,41,42,43,44. It is therefore likely that the above effects will be greatly amplified by non-linear responses of the system to collective excitations induced by the absorption of very short and intense X-ray pulses.
Methods
Sample preparation
Samples of the oxide glasses were prepared in the form of disks of 5 mm diameter by cutting bulk material with a diamond drill bit. The disks were mechanically polished to a thickness of 50 μm for SiO2 and of 20 μm for GeO2, in order to get the best compromise between the scattering signal and the speckle contrast. Bulk SiO2 was a commercial grade Spectrosil (SiO2-bis from Suprasil F300 with less than 1 ppm OH), while GeO2 was prepared by the usual melt-quenching procedure. Zr65Cu27.5Al7.5 metallic glasses were prepared by melt spinning in the University of Göttingen. The resulting ribbons had a thickness of about 40 μm.
XPCS measurements
We performed several XPCS experiments at the beamline ID10 at ESRF by using 8.1 KeV radiation produced by three undulator sources. The coherent part of the beam (8 μm × 10 μm V × H full width half maximum) was selected by rollerblade slits placed upstream of the sample. The incoming intensity at the sample position was monitored continuously with a scintillation detector counting the photons scattered by air. The absolute incident flux is estimated by normalizing to scattered intensities from kapton foils45. The samples were inserted in a homemade resistively heated furnace mounted on a diffractometer in horizontal scattering geometry. The coherently scattered photons (speckles) were recorded by an Andor CCD device installed at ≈70 cm from the sample on a detector arm that was rotating around the sample to cover the Q–range 0.3–4 Å−1. Correlation functions were obtained following the analysis described in ref. 46. Oxides glasses were measured at room temperature while Cu65Zr27.5Al7.5 was annealed at T = 413 K (thus at T/Tg = 0.59). The choice of this temperature was dictated by the requirement to place the system in the temporal window where the decay time remains constant and sufficiently fast with τ ≤ 103 s in standard working conditions at maximum flux (8.1 keV, no attenuators). This situation can be achieved by working at high temperature in the glassy state, where metallic glasses display stationary dynamics, likely related to an intermittent mechanism of aging34. At lower temperatures the dynamics is dominated by the typical fast aging of rapidly quenched metallic glasses17, 21 making the test extremely challenging as it would be difficult to disentangle X-rays induced effects and spontaneous changes of the decay time related to aging. For all samples, the measured contrast was ≈2–5% depending on the experimental conditions.
References
Neutron and Synchrotron Radiation for Condensed Matter Studies (eds. Baruchel, J. et al.), (Springer, 1994).
Wang, J. et al. Radiation damage in soft X-ray microscopy. J. Electron. Spectrosc. Relat. Phenom 170, 25 (2009).
Ravelli, R. B. G. & McSweeney, S. M. The ‘fingerprint’ that X-rays can leave on structures. Structure 8, 315 (2000).
Teng, T. & Moffat, K. Primary radiation damage of protein crystals by an intense synchrotron X-ray beam. J. Synch. Rad. 7, 313 (2000).
Gonzalez, A. & Nave, C. Radiation damage in protein crystals at low temperature. Acta Cryst. D 50, 874–877 (1994).
Weik, M. et al. X-ray radiation produces specific chemical and structural damage to protein structures. Proc. Natl. Acad. Sci. 97, 623–628 (2000).
Ravelli, R. B. G. et al. Specific Radiation Damage Can Be Used to Solve Macromolecular Crystal Structures. Structure 11, 217–224 (2003).
Holton, J. M. A beginner’s guide to radiation damage. J. Synch. Rad. 16, 133 (2009).
Howells, M. R. et al. An assessment of the resolution limitation due to radiation-damage in X-Ray diffraction microscopy. J. Electron. Spectrosc. Relat. Phenom. 170, 4 (2009).
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E. & Hajdu, J. Potential for biomolecular imaging with femtosecond X-ray pulses. Nature 406, 752–757 (2000).
Chapman, H. N. et al. Femtosecond X-ray protein nanocrystallography. Nature 470, 73–77 (2011).
Griscom, D. L. Nature of defects and defect generation in optical glasses. Proc. of SPIE 541, 38–59 (1985).
Kinchin, G. H. & Pease, R. S. The Displacement of Atoms in Solids by Radiation. Rep. Prog. Phys. 18, 1 (1955).
Leitner, M., Stana, M., Ross, M. & Sepiol, B. Acceleration of atomic dynamics due to localized energy depositions under X-ray irradiation. arXiv:1510.01918v1 (2015).
Madsen, A., Fluerasu, A. & Ruta, B. Structural dynamics of materials probed by X-ray photon correlation spectroscopy, Synchrotron Light Sources and Free-Electron Lasers. 1–21, (Springer International Publishing, 2015).
Leitner, M., Sepiol, B., Stadler, L. M., Pfau, B. & Vogl, G. Atomic diffusion studied with coherent x-rays. Nat. Mater. 8, 717–720 (2009).
Ruta, B. et al. Atomic-scale relaxation dynamics and aging in a metallic glass probed by x-ray photon correlation spectroscopy. Phys. Rev. Lett. 109, 165701 (2012).
Huang, P. H. et al. Imaging Atomic Rearrangements in Two-Dimensional Silica Glass: Watching Silica’s Dance. Science 342, 224 (2013).
Ruta, B. et al. Revealing the fast atomic motion of network glasses. Nat. Commun. 5, 3939 (2014).
Ross, M., Stana, M., Leitner, M. & Sepiol, B. Direct observation of atomic network migration in glass. New J. Phys. 16, 093042 (2014).
Giordano, V. M. & Ruta, B. Unveiling the structural arrangements responsible for the atomic dynamics in metallic glasses during physical aging. Nat. Commun. 7, 10344 (2016).
Evenson, Z. et al. β relaxation and low-temperature aging in a au-based bulk metallic glass: From elastic properties to atomic-scale structure. Phys. Rev. B 89, 174204 (2014).
Scudino, S. et al. Length scale-dependent structural relaxation in Zr57.5Ti7. 5Nb5Cu12.5Ni10Al7.5 metallic glass. J. Alloys Compd. 639, 465–469 (2015).
Welch, R. C. et al. Dynamics of Glass Relaxation at Room Temperature. Phys. Rev. Lett. 110, 265901 (2013).
Malik, A. et al. Coherent X-Ray Study of Fluctuations during Domain Coarsening. Phys. Rev. Lett. 81, 5832 (1998).
Cipelletti, L. et al. Universal non-diffusive slow dynamics in aging soft matter. Faraday Discuss. 123, 237 (2003).
Ferrero, E. E., Martens, K. & Barrat, J.-L. Relaxation in yield stress systems through elastically interacting activated events. Phys. Rev. Lett. 113, 248301 (2014).
Arbe, A. & Colmenero, J. Characterization of the ‘simple-liquid’ state in a polymeric system: coherent and incoherent scattering functions. Phys. Rev. E 80, 041805 (2009).
Busselez, R. et al. The non-Gaussian dynamics of glycerol. J. Phys.: Condens. Matter 23, 505102 (2011).
Dolle, F. E. et al. XPCS Investigation of the Dynamics of Filler Particles in Stretched Filled Elastomers. Macromol. 45, 8691–8701 (2012).
Shinohara, Y., Yamamoto, N., Kishimoto, H. & Amemiya, Y. X-ray irradiation induces local rearrangement of silica particles in swollen rubber. J. Synch. Rad. 22, 119–123 (2015).
Vodnala, P. et al. Radiation damage limits to XPCS studies of protein dynamics. AIP Conf. Proc. 1741, 050026 (2016).
Hobbs, L. W., Clinard, F. W. Jr., Zinkle, S. J. & Ewing, R. C. Radiation Effects in Ceramics. J. Nuclear Mat. 216, 291–321 (1994).
Evenson, Z. et al. X-ray photon correlation spectroscopy reveals intermittent aging dynamics in a metallic glass. Phys. Rev. Lett. 115, 175701 (2015).
Ruta, B., Baldi, G., Monaco, G. & Chushkin, Y. Compressed correlation functions and fast aging dynamics in metallic glasses. J. Chem. Phys. 138, 054508 (2013).
Shpyrko, O. X-ray photon correlation spectroscopy. J. Synch. Rad. 21, 1057–1064 (2014).
Eriksson, M., van der Veen, J. F. & Quitmann, C. Diffraction-limited storage rings – a window to the science of tomorrow. J. Synch. Rad 21, 837–842 (2014).
O’Shea, P. G. & Freund, H. P. Free-Electron Lasers: Status and Applications. Science 292, 8 (2001).
Stephenson, G. B., Robert, A. & Grübel, G. X-ray spectroscopy: Revealing the atomic dance. Nat. Mat. 8, 702–703 (2008).
Carnis, J. et al. Demonstration of Feasibility of X-ray Free Electron Laser Studies of Dynamics of Nanoparticles in Entangled Polymer Melts. Sci. Rep. 4, 6017 (2014).
Lehmkühler, F. et al. Single Shot Coherence Properties of the Free-Electron Laser SACLA in the Hard X-ray Regime. Sci. Rep. 4, 5234 (2014).
Lehmkühler, F. et al. Sequential Single Shot X-ray Photon Correlation Spectroscopy at the SACLA Free Electron Laser. Sci Rep. 5, 17193 (2015).
Alonso-Mori, R. et al. The X-ray Correlation Spectroscopy instrument at the Linac Coherent Light Source. J. Synch. Rad. 22, 508–513 (2015).
Hruszkewycz, S. O. et al. High Contrast X-ray Speckle from Atomic-Scale Order in Liquids and Glasses. Phys. Rev. Lett. 109, 185502 (2012).
Zontone, F., Madsen, A. & Konovalov, O. Measuring The Source Brilliance at An Undulator Beamline. AIP Conf. Proc. 1234, 603–606 (2010).
Chushkin, Y., Caronna, C. & Madsen, A. A novel event correlation scheme for X-ray photon correlation spectroscopy. J. Appl. Cryst. 45, 807 (2012).
Acknowledgements
Prof. K. Samwer and the University of Göttingen is gratefully acknowledged for the metallic glass. We acknowledge H. Vitoux, K. L’Hoste and L. Claustre for the technical support during the XPCS experiments, and Del Maschio for the sample preparation. We gratefully thank A. Madsen and M. Di Michiel for fruitful discussions.
Author information
Authors and Affiliations
Contributions
B.R. conceived the project. B.R., F.Z., Y.C., G.B., G.P., G.M. and B. Rufflé performed the experiments; Y.C. provided the programs for the XPCS data analysis; B.R. analysed the data. G.B. and B. Rufflé provided the samples; All authors discussed the results. B.R. wrote the manuscript with contributions from all authors.
Corresponding author
Ethics declarations
Competing Interests
The authors declare that they have no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Ruta, B., Zontone, F., Chushkin, Y. et al. Hard X-rays as pump and probe of atomic motion in oxide glasses. Sci Rep 7, 3962 (2017). https://doi.org/10.1038/s41598-017-04271-x
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-017-04271-x
This article is cited by
-
X-ray driven and intrinsic dynamics in protein gels
Scientific Reports (2023)
-
Dynamics at the crystal-melt interface in a supercooled chalcogenide liquid near the glass transition
Scientific Reports (2020)
-
Coherent X-ray spectroscopy reveals the persistence of island arrangements during layer-by-layer growth
Nature Physics (2019)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.