DOI: 10.4244/EIJV7I4A84

Use of three-dimensional optical coherence tomography to verify correct wire position in a jailed side branch after main vessel stent implantation

Niels R. Holm1, MD; Shengxian Tu2, MSc; Evald H. Christiansen1, MD, PhD; Johan H.C. Reiber2, PhD; Jens Flensted Lassen1, MD, PhD; Leif Thuesen1, MD, DMSci; Michael Maeng1, MD, PhD

A 59-year-old man with ST-segment elevation myocardial infarction was admitted for primary percutaneous coronary intervention due to a severe stenosis in the proximal left anterior descending artery (LAD) at the bifurcation of the first diagonal branch (Medina type 1,1,1) with TIMI flow 2 in both branches (Panel A). After thrombus aspiration and pre-dilatation of the side branch and the main vessel, the LAD was stented with a 3.0×23mm sirolimus-eluting stent (Cypher Select+; Cordis, Miami Lakes, FL, USA), resulting in severe ostial side branch (SB) stenosis (Panel B). To facilitate SB access, proximal optimisation technique (POT)1 was performed by dilating the proximal segment with a short 3.5×8mm non-compliant balloon. After rewiring the SB, wire position was controlled by optical coherence tomography (OCT) (C7; St. Jude Medical, St. Paul, MN, USA) and 3D-OCT images were reconstructed by use of an OCT-XA registration software package, prototype version = (Medis medical imaging systems bv, Leiden, The Netherlands)2. The side branch wire was found to pass through the stent lumen into the narrow SB ostium without passing under proximal stent struts (Panel C). Final kissing balloon dilatation (FKBD) was performed by simultaneously inflating 3.0×15mm non-compliant balloons at 14 atm (Panel D). 3D-OCT after FKBD showed adequate opening of the SB ostium and some distortion (ratio of longest/shortest stent diameter=1.4) of the proximal part of the stent was seen (Panel E). The longest diameter in the oval shaped proximal main vessel stent was in the same plane as the SB offspring due to FKBD with parallel balloons. The ostia of both distal vessels were visible from the proximal end of the stent (PanelE). This could indicate a favourable anatomy facilitating flow into both distal branches.

Figure 1. A) Coronary angiogram pre PCI; B) After main vessel stenting; C) 3D-OCT showing wirer position in jailed side branch; D) Final kissing balloon dilatation with parallel balloons; 3D-OCT showing proximal stent distortion and opening of ostia after kissing balloon dilatation. See text for details.

This is the first time highly informative 3D-OCT images have been reconstructed in a few steps by a novel OCT-XA software package. In this case the 3D-OCT images provided evidence of correct re-wiring and successful FKBD. A larger series is warranted to provide further insight into optimal re-wiring of the SB and subsequent outcome after FKBD.

Conflict of interest statement

N.Holm received speaker fees, travel grants and unrestricted research grants from St. Jude Medical and a research grant from Cordis. S. Tu has a research appointment at the Leiden University Medical Center and is employed by Medis medical imaging systems bv. E. Christiansen has received speaker fees and a travel grant from Cordis. J. Reiber has a part-time appointment as professor of medical imaging at the Leiden University Medical Center and is CEO of Medis medical imaging systems bv. J.Lassen has recieved speaker fees and unrestricted research grants from Cordis and st. Jude Medical. L. Thuesen has recieved unrestricted reseach grants form Cordis. M. Maeng has received travel grants and speaker fees from Cordis.

Volume 7 Number 4
Aug 30, 2011
Volume 7 Number 4
View full issue


Key metrics

On the same subject

Snapshot

May 20, 2024
Continue learning with EuroIntervention!
free

Editorial

10.4244/EIJ-E-24-00027 May 20, 2024
Can DAPT be discontinued at one month after PCI in high bleeding risk patients presenting with ACS?
Hong M and Lee Y
free

Editorial

10.4244/EIJ-E-24-00015 May 20, 2024
When can we discharge patients after chronic total occlusion percutaneous coronary intervention?
Lombardi W and Azzalini L
free

Debate

10.4244/EIJ-E-24-00014 May 20, 2024
Atherectomy for calcified plaques: orbital for most? Pros and cons
Kirtane A and Ribichini F
free

Editorial

10.4244/EIJ-E-24-00017 May 20, 2024
Is this the end of the ultrathin-strut hypothesis?
Bangalore S and Finn A
free

Original Research

10.4244/EIJ-D-23-00605 May 20, 2024
Impact of coronary calcium morphology on intravascular lithotripsy
McInerney A et al

Original Research

10.4244/EIJ-D-23-00563 May 20, 2024
Ultrathin-strut versus thin-strut stent healing and outcomes in preclinical and clinical subjects
Ikegami R et al
Trending articles
314.33

State-of-the-Art Review

10.4244/EIJ-D-21-00695 Nov 19, 2021
Transcatheter treatment for tricuspid valve disease
Praz F et al
free
74.6

Clinical research

10.4244/EIJ-D-22-01062 Aug 21, 2023
Impact of mitral regurgitation aetiology on the outcomes of transcatheter aortic valve implantation
Doldi PM et al
42.95

Clinical research

10.4244/EIJ-D-23-00282 Jul 17, 2023
Early safety and feasibility of a first-in-class biomimetic transcatheter aortic valve - DurAVR
Kodali SK et al
X

The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

EuroPCR EAPCI
PCR ESC
Impact factor: 6.2
2022 Journal Citation Reports®
Science Edition (Clarivate Analytics, 2023)
Online ISSN 1969-6213 - Print ISSN 1774-024X
© 2005-2024 Europa Group - All rights reserved