Abstract 


Background

Lumen-apposing metal stents (LAMS) are rapidly being used in endoscopic interventional drainage procedures and have started to replace the self-expanding metal stents (SEMSs). Its use in gallbladder drainage (GBD) is limited by lack of good-quality studies, and data are scarce on its safety.

Methods

We conducted a comprehensive search of multiple electronic databases and conference proceedings including PubMed, Embase, and Web of Science databases (from inception through July 2018) to identify studies that reported on the use of LAMS in GBD. The outcomes measured were the pooled rates of all adverse events (AEs), pooled rates of early AEs and pooled rates of delayed AEs.

Results

A total of 8 studies (393 patients) were included. The pooled rate of all AEs was 12.7% (95% CI 8.4-18.7, I2= 7.7) compared to 17.5% (95% CI 10.2-28.2, I2= 65.1) with other SEMS, P = 0.39. The rate of early AEs with LAMS in endoscopic ultrasound-GBD (EUS-GBD) was 6.5% (95% CI 4.2-10, I2= 1.2), and the rate of delayed AEs was 8.3% (95% CI 5.8-11.9, I2 = 4.8). The rate of recurrent cholecystitis and/or cholangitis was 4.6% (95% CI 2.6-9.5, I2= 0) and the pooled rate of death was 5% (95% CI 2.6-9.5, I2 = 36.4).

Conclusion

We report an overall AE rate of 13% with LAMS in EUS-GBD. Early AE risk appears to be 6.5% and delayed AE risk appears to be 8%. Our results are analyzed out of good-quality studies, with minimal to zero heterogeneity.

Free full text 


Logo of endoultraHomeCurrent issueInstructionsSubmit article
Endosc Ultrasound. 2019 Jul-Aug; 8(4): 241–248.
Published online 2019 May 9. https://doi.org/10.4103/eus.eus_63_18
PMCID: PMC6714485
PMID: 31115387

Adverse events with lumen-apposing metal stents in endoscopic gallbladder drainage: A systematic review and meta-analysis

Associated Data

Supplementary Materials

Abstract

Background:

Lumen-apposing metal stents (LAMS) are rapidly being used in endoscopic interventional drainage procedures and have started to replace the self-expanding metal stents (SEMSs). Its use in gallbladder drainage (GBD) is limited by lack of good-quality studies, and data are scarce on its safety.

Methods:

We conducted a comprehensive search of multiple electronic databases and conference proceedings including PubMed, Embase, and Web of Science databases (from inception through July 2018) to identify studies that reported on the use of LAMS in GBD. The outcomes measured were the pooled rates of all adverse events (AEs), pooled rates of early AEs and pooled rates of delayed AEs.

Results:

A total of 8 studies (393 patients) were included. The pooled rate of all AEs was 12.7% (95% CI 8.4-18.7, I2 = 7.7) compared to 17.5% (95% CI 10.2-28.2, I2 = 65.1) with other SEMS, P = 0.39. The rate of early AEs with LAMS in endoscopic ultrasound-GBD (EUS-GBD) was 6.5% (95% CI 4.2-10, I2 = 1.2), and the rate of delayed AEs was 8.3% (95% CI 5.8-11.9, I2 = 4.8). The rate of recurrent cholecystitis and/or cholangitis was 4.6% (95% CI 2.6-9.5, I2 = 0) and the pooled rate of death was 5% (95% CI 2.6-9.5, I2 = 36.4).

Conclusion:

We report an overall AE rate of 13% with LAMS in EUS-GBD. Early AE risk appears to be 6.5% and delayed AE risk appears to be 8%. Our results are analyzed out of good-quality studies, with minimal to zero heterogeneity.

Keywords: Adverse events, gallbladder drainage, lumen-apposing metal stents, self-expanding metal stents

INTRODUCTION

Lumen-apposing metal stents (LAMS) were first introduced in 2012 and made widely clinically available in 2015.[1] The different LAMS commercially available for use are the AXIOS stent (by Xlumena Inc., Mountain View, CA, USA); the Niti-S SPAXUS and NAGI stents (by Taewoong-Medical Co., Ilsan, Korea); the AIX stent (by Leufen Medical, Aachen, Germany); and the brachiocephalic fistula (BCF) stent (by Hanaro MRI Tech). All are made of nitinol wire and fully covered with silicon. The shape of a LAMS is designed to keep the target object (pseudocyst, walled-off necrosis, etc.) closely apposed to the gastrointestinal (GI) lumen.[2] They are now widely employed in many clinical settings, including the treatment of benign luminal GI strictures,[3] endoscopic drainage of pancreatic fluid collections,[4] endoscopic gallbladder drainage[5] (E-GBD), and endoscopic gastrojejunostomy.[6]

Like any other advanced endoscopic intervention, the use of LAMS carries risks of adverse events (AEs). Early recognition of AEs is critical to minimize morbidity and mortality. These AEs can be immediate during the stent deployment or delayed. Data are limited regarding the safety of LAMS when used to provide E-GBD. The reported results are highly varied as the current literature consists of many small retrospective case series. Recently published qualitative and quantitative reviews are limited by inclusion of these small studies. Small and low-quality studies add to the heterogeneity and negatively impact the overall reliability of the results.[7] Despite the limited data on the safety of LAMS, there has been clinical adoption of this stent globally in setting where a LAMS is used, and studies have suggested that it can be safely used in an outpatient setting.[8]

We conducted this meta-analysis, using only good-quality studies, to better understand and quantify the AE rates with the use of LAMS in GBD.

METHODS

Search strategy

We conducted a comprehensive search of several databases and conference proceedings including PubMed, Embase, and Web of Science databases (earliest inception to July 2018). We followed the preferred reporting items for systematic reviews and meta-analyses guidelines,[9] by using predefined protocol, to identify studies reporting the use of LAMS in GBD. An experienced medical librarian using inputs from the study authors helped with the literature search.

Keywords used in the search included a combination of “lumen-apposing metal stent,” “AXIOS stent,” “SPAXUS stent,” “NAGI stent,” “NITI-S stent,” “AIX stent,” “BCF stent,” “endoscopic ultrasound guided,” and “gall-bladder drainage.” The search was restricted to studies in human subjects and published in English language in peer-reviewed journals. Three authors (M.B., S.M., A.R.) independently reviewed the title and abstract of studies identified in primary search and excluded studies that did not address the research question, based on prespecified exclusion and inclusion criteria. The full text of remaining articles was reviewed to determine whether it contained relevant information. Any discrepancy in article selection was resolved by consensus and in discussion with a coauthor.

The bibliographic section of the selected articles as well as the systematic and narrative articles on the topic was manually searched for additional relevant articles.

Study selection

In this meta-analysis, we included cohort studies that met the following criteria: (1) use of LAMS in GBD and (2) data on AEs attributed to LAMS. Studies irrespective of the reason for GBD, the size of LAMS, the commercial type of LAMS, geography, and abstract/manuscript status were included as long as they provided data needed for the analysis.

Following were our exclusion criteria: (1) studies that provided no data on AEs attributed to LAMS, (2) studies that reported on self-expanding metal stents (SEMSs) that were not lumen apposing, and (3) <30 patients in the study cohort.

In case of multiple publications from the same cohort, data from the most recent and/or most appropriate comprehensive report were included. In our search process, we encountered two such studies, one by Jang et al.[10] and other by Irani et al.[11]

Data abstraction and quality assessment

Data on study-related outcomes in the individual studies were abstracted onto a standardized form by at least 2 authors (M. B., S. M.) independently, and 3 authors (M. B., S. M., G. R.) did the quality scoring independently.

Using a scale modified from the Newcastle–Ottawa scale for cohort studies assessed the quality of included studies.[12] This quality score consisted of 6 questions: representative of the average adult in the community (1 point for population-based studies, 0.5 point for multicenter studies; 0 point for a single-center hospital-based study); large cohort size (1 point if >30 patients, 0.5 point if between 15 and 30 patients, 0 point if <15 patients); information on overall AEs (1 point if reported; 0 point if not reported); information on subtypes of AEs (1 point if reported, 0 point if not reported); type of article write-up (1 point if original manuscript, 0.5 point if abstract); and attrition rate (1 point if all patients were accounted for, 0.5 point if <50% patients lost to follow-up, 0 point if >50% patients lost to follow-up). A score of ≥5, 3–4, and <3 was considered suggestive of high-quality, medium-quality, and low-quality study, respectively.

Outcomes assessed

The primary analysis focused on assessing the pooled rate of overall AEs in EUS-GBD with LAMS. The pooled rate of AE in EUS-GBD with other SEMS was used as a comparator.

Our secondary analysis focused on calculating the following in EUS-GBD with LAMS:

  1. Pooled rates of early AE; with further classification into bleeding, bile leak, stent occlusion, perforation, and stent migration

  2. Pooled rates of delayed AE; with further classification of the delayed AEs into bleeding, bile leak, stent occlusion, and stent migration

  3. Pooled rates of recurrent cholecystitis and/or cholangitis and death, and

  4. Pooled rates of technical success and clinical success.

Definitions

Majority of studies defined AEs as any procedure, drain or stent-related event. Studies did not mention any predetermined criterion to define bile leak, perforation, stent occlusion, and stent migration. These were considered as AEs even if the patient suffered no clinical symptoms out of the event. Bleeding was defined as significant if requiring blood product transfusion, endoscopic therapy, and radiologic or surgical interventions. AEs reported within the first 2 weeks of EUS-guided LAMS placement were considered early, and the ones reported after 2 weeks of intervention were considered delayed.

Technical success was defined as the ability to place a transmural LAMS into the gallbladder and/or the bile duct as determined by the flow of bile and/or pus. Clinical success was defined as the resolution of symptoms, laboratory abnormalities, and/or radiologic abnormalities. There was variability in the laboratory resolution cutoff among studies, with majority defining it as a decrease in bilirubin levels to <10% of initial levels and/or <50% of initial levels with resolution of clinical symptoms.

Statistical analysis

We used meta-analysis techniques to calculate the pooled estimates in each case following the methods suggested by DerSimonian and Laird using the random effects model.[13] When the incidence of an outcome was zero in a study, a correction of 0.01 was added to the number of incident cases before statistical analysis.[14] We assessed heterogeneity between study-specific estimates using two methods, the Cochran Q statistical test for heterogeneity and the I2 statistic.[15,16] In this, values of <30%, 30%–60%, 61%–75%, and >75% were suggestive of low, moderate, substantial, and considerable heterogeneity, respectively.[17] Since random effects model estimates an average effect, we also calculated the 95% prediction interval, which deals with the dispersion of the effects.[18,19] Publication bias was ascertained, qualitatively, by visual inspection of funnel plot, and quantitatively, by the Egger test.[20]

All analyses were performed using comprehensive meta-analysis software, version 3 (BioStat, Englewood, NJ, USA).

RESULTS

Search results and population characteristics

From an initial total of 658 citations identified using our search strategy, our search of the database resulted in 36 studies that met our inclusion criteria. Of these, 18 studies were excluded because they had <30 patients in their study cohort and 10 studies were excluded because of other methods and/or routes used to drain the gallbladder. A total of 8 studies[5,11,21,22,23,24,25,26] were included in the final analysis. All studies used the AXIOS stent except one study that used the Spaxus stent.[25] The schematic diagram of study selection is illustrated in Figure 1. Table 1 describes the study and population characteristics.

An external file that holds a picture, illustration, etc.
Object name is EUS-8-241-g001.jpg

Study flow and selection. LAMS: Lumen-apposing metal stent

Table 1

Study and population characteristics

StudyMost common clinical indicationMale %Age (years)Procedure Time (min)StentFollow-up period (days)Total nAll adverse eventsSuccessStudy quality

TechnicalClinical
Kunda et al., 2016, USA[23]Malignancy5449-9311 to 65HA & CA151+/-1455785654/56High
Anderloni et al., 2018, Italy[21]Malignancy5471.3+/-12.410 to 104HA18-41135532/3430/32Medium
Walter et al., 2016, Netherlands[24]Acute Cholecystitis37NRNRCA298+/-823042726/27High
Irani et al., 2017, USA[11]Acute Cholecystitis6425-8718 to 52HA & CA1-6214564443/44High
Dollhopf et al., 2017, Germany[5]Acute Cholecystitis48mean 75+/-118 to 60HA201+/-2267557471/74High
Teoh et al., 2018, China[25]Acute Cholecystitis and Malignancy5668+/-13NRSpaxus29-383603229/32High
Teoh et al., 2017, China/Spain[26]Acute Cholecystitis5182.7+/-7.9NRHA & CA450.7+/-3435985753High
Garcia-Alonso et al., 2018, Spain[22]Multiple indications6557.9-83.6NRHA & CA31-246.55611NRNRMedium

NR: Not reported, AE: Adverse events; HA: Hot-AXIOS, CA: Cold-AXIOS. (Table 1. Study and population characteristics)

Majority of the population consisted of males (37%–65%), with an age range of 25–93 years. Procedure time was reported in the range of 8–104 min. Acute cholecystitis and/or malignancy was the clinical indication for EUS-GBD. Period of follow-up ranged from 1 day to 411 days.

Characteristics and quality of included studies

Table 1 describes the study and population characteristics. None of the studies were population based. Six studies[5,11,23,24,25,26] were multicenter based and the rest 2[21,22] were from single center. All studies had more than or equal to 30 patients. All studies reported on the overall AEs but were variable in the subtypes. One study by Garcia-Alonso et al.[22] reported only on stent migration and gastrointestinal bleeding. All studies except two by Anderloni et al. and Teoh et al.[21,25] were full manuscripts and all studies had adequate follow up of their study population. Overall, 6 studies[5,11,23,24,25,26] were considered to be of high quality and the rest 2[21,22] were of medium quality. None were of low quality. The study by Walter et al.[24] was a prospectively designed study [Supplement Table 1 Study quality assessment].

Supplementary Table 1

Study quality assessment

QUESTIONSCORING SCHEMEKunda et al., 2016[23]Anderloni et al., 2018[21]Walter et al., 2016[24]Irani et al., 2017[11]Dollhopf et al., 2017[5]Teoh et al., 2018[25]Teoh et al., 2017[26]Garcia-Alonso et al., 2018[22]
Representative of the average adult in the community1 point: population-based studies, 0.5 point: multicenter studies, 0 point: single-center hospital-based study0.500.50.50.50.50.50
Cohort size1 point: >30 patients 0.5 point: 30-15 patients 0 point: <15 patients110.511111
Information on overall adverse events1 point: reported with clarity 0 point: not reported11111111
Information on adverse event sub-types1 point: reported with clarity 0 point: not reported1111110.50.5
Type of article write up1 point: original manuscript 0.5 point: abstract10.51110.511
Attrition rate1 point: all patients accounted for 0.5 point: <50% not accounted for 0 point: >50% not accounted for11111111
TOTAL(maximum=6; high >5; medium 5-3; low<3)5.54.555.55.5554.5

Adverse events in EUS-gallbladder drainage with lumen-apposing metal stents

The rate of all AEs with LAMS in EUS-GBD (8 studies,[5,11,21,22,23,24,25,26] 393 patients, 47 events) was 12.7% (95% CI 8.4-18.7, I2 = 7.7), as compared to 17.5% (95% CI 10.2-28.2, I2 = 65.1) with the use of other SEMS (6 studies,[27,28,29,30,31,32] 154 patients), without any statistical significance to the difference, P = 0.39 [Figure 2].

An external file that holds a picture, illustration, etc.
Object name is EUS-8-241-g002.jpg

Forest plot - overall adverse events

Rates of AE subtypes are as given below:

  • Bleeding: 4.2% (95% CI 2.2-7.9, I2 = 31.8)

  • Bile leak: 2.4% (95% CI 1.1-5.1, I2 = 0)

  • Stent occlusion: 5.2% (95% CI 3-8.7, I2 = 0)

  • Perforation: 2.3% (95% CI 1.1-4.7, I2 = 0)

  • Stent migration: 3.2% (95% CI 1.8-5.8, I2 = 0). [forest plots: Supplement Figure 1, 4, 7, 8, 9].

Procedure and/or lumen-apposing metal stents-related early adverse events

The rate of all early AE with LAMS in EUS-GBD (8 studies,[5,11,21,22,23,24,25,26] 393 patients, 19 events) was 6.5% (95% CI 4.2-10, I2 = 1.2) [Figure 3].

An external file that holds a picture, illustration, etc.
Object name is EUS-8-241-g003.jpg

Forest plot - overall early adverse events

Rates of early AE subtypes are as given below:

  • Bleeding: 2.6% (95% CI 0.9-7.2, I2 = 47.1)

  • Bile leak: 1.3% (95% CI 0.5-3.3, I2 = 0)

  • Stent occlusion: No events

  • Perforation: 2.3% (95% CI 1.1-4.7, I2 = 0)

  • Stent migration: 1.5% (95% CI 0.6-3.5, I2 =0). [forest plots: Supplement Figure 2, 5, 8, 10].

Lumen-apposing metal stents-related delayed adverse events; recurrent cholecystitis and/or cholangitis; death

The rate of all delayed AE with LAMS in EUS-GBD (8 studies,[5,11,21,22,23,24,25,26] 393 patients, 28 events) was 8.3% (95% CI 5.8-11.9, I2 = 4.8) [Figure 4].

An external file that holds a picture, illustration, etc.
Object name is EUS-8-241-g004.jpg

Forest plot - overall delayed adverse events

Rates of delayed AE subtypes are as given below:

  • Bleeding: 2% (95% CI 0.9-4.1, I2 = 0)

  • Bile leak: 1.9% (95% CI 0.8-4.3, I2 = 0)

  • Stent occlusion: 5.2% (95% CI 3-8.7, I2 = 0)

  • Stent migration: 3% (95% 1.5-5.8, I2 = 0).

    [forest plots: Supplement Figure 3, 6, 7, 11].

The rate of recurrent cholecystitis and/or cholangitis (6 studies,[5,11,22,24,25,26] 301 patients, 11 events) was 4.6% (95% CI 2.6-8.0, I2 = 0) [Supplement Figure 12].

The rate of death (7 studies,[5,11,21,23,24,25,26] 337 patients, 15 events) was 5% (95% CI 2.6-9.5, I2 = 36.4) [Supplement Figure 13]. All adverse events reported are summarized in Table 2 and all pooled results are summarized in Table 3. Forest plots for all adverse event sub-types are given in supplementary material.

Table 2

Breakdown of adverse events

StudyTotal nAll aeEarly Adverse-eventsDelayed Adverse-eventsRecurrent Cholecystitis/CholangitisDeath


AllBleedingBile LeakStent occlusionPerforationStent migrationAllBleedingBile LeakStent occlusionStent migration
Kunda et al., 2016[23]57841002140040NR2
Anderloni et al., 2018[21]35500000051031NR1
Walter et al., 2016[24]3040000004002025
Irani et al., 2017[11]4562110004112031
Dollhopf et al., 2017[5]7553100112100133
Teoh et al., 2018[25]3600000000000020
Teoh et al., 2017[26]5983000215221003
Garcia - Alonso et al., 2018[22]561177NRNRNRNR40NRNR41NR

NR: not reported, AE: adverse events; HA: Hot-AXIOS, CA: Cold-AXIOS

Table 3

EUS-GBD with LAMS: Summary of all results

GroupOverallEarlyDelayed

(95% CI, I2%)
Adverse events12.7% (8.4-18.7, 7.7)6.5% (4.2-10,1.2)8.3% (5.8-11.9, 4.8)
Bleeding4.2% (2.2-7.9, 31.8)2.6% (0.9-7.2, 47.1)2% (0.9-4.1, 0)
Bile leak2.4% (1.1-5.1, 0)1.3% (0.5-3.3, 0)1.9% (0.8-4.3, 0)
Stent occlusion5.2% (3-8.7, 0)No events5.2% (3-8.7, 0)
Perforation2.3% (1.1-4.7, 0)2.3% (1.1-4.7, 0)Not reported
Stent migration3.2% (1.8-5.8, 0)1.5% (0.6-3.5, 0)3% (1.5-5.8, 0)
Cholecystitis4.6% (2.6-8.0, 0)--
Death5% (2.6-9.5, 36.4)--
Technical success94.9% (90.8-97.3, 25.5)--
Clinical success94.6% (91.4-96.7, 0)--

Technical success and clinical success

The rates of technical success and clinical success with LAMS in EUS-GBD (8 studies,[5,11,21,22,23,24,25,26] 393 patients) were 94.9% (95% CI 90.8–97.3, I2 = 25.5) and 94.6% (95% CI 91.4-96.7, I2 =0), respectively [forest plots: Supplement Figure 14 and 15].

Validation of meta-analysis results

Sensitivity analysis

To assess whether any one study had a dominant effect on the meta-analysis, we excluded one study at a time and analyzed its effect on the main summary estimate. On this analysis, no single study significantly affected the outcome or the heterogeneity.

Heterogeneity

Based on Q statistics, and I2 analysis for heterogeneity, low (I2 < 30) to no (I2 = 0) heterogeneity was noted in the analyses of the primary and secondary outcomes of LAMS in EUS-GBD.

Publication bias

Based on visual inspection of the funnel plot as well as quantitative measurement that used the Egger regression test, there was no evidence of publication bias [Supplement Figure 16 - funnel plot].

DISCUSSION

Our meta-analysis is the first study to report pooled data from good-quality studies, avoiding small case studies and reports, on the AEs of LAMS in GBD. We report an overall AEs rate of 13% with LAMS as compared to 17.5% with other SEMS, with no statistical significance. The early AE rate was 6.5%, and the delayed AE rate was 8%.

The calculated early versus delayed rates for bleeding (2.6% vs 2%), bile leak (1.3% vs 1.9%), and stent migration (1.5% vs 3%) were comparable. The calculated risk of perforation was 2.3% that was reported only as an early AE. The calculated rate of stent occlusion was 5.2% that was reported only as a delayed AE. The rate of cholecystitis and/or cholangitis was 4.6%, and the rate of death was 5%. Our calculated rate of death needs to be interpreted with caution. Majority of studies reported death as the end outcome and were mostly related to the underlying disease process. None of the reported death events were related to the procedure and/or the use of LAMS. The calculated technical success was 94.9% and clinical success was 94.6%.

Why do this study and how do our results compare with other recently published similar studies? At the time this study was generated, at least four other systematic reviews were published on similar topic. These are studies by Han et al.,[33] Manta et al.,[34] Kalva et al.,[35] and Jain et al.[36] All studies, including our study, were consistent in the reporting of calculated technical success (93.86%–95%) and clinical success (92.48%–93%) rates. Nevertheless, our study differs significantly from these studies in the calculation and reporting of the AEs. The study by Jain et al.[36] was a qualitative review without a quantitative pooling of results. Manta et al.[34] did not report the pooled rates of AEs. Kalva et al.[35] included the BONA-AL stent (Standard Sci Tech Inc., Seoul, Korea) in their analysis, which technically does not generate lumen-apposing force and hence is not considered a LAMS. Han et al.[33] studied the use of LAMS in pancreatic fluid collections and GBD. They reported a pooled AE rate of 17.1% with LAMS in EUS-GBD without any mention of heterogeneity and/or validation statistics for their meta-analysis. All these studies were severely limited by the inclusion of multiple small studies.

The strengths of our review are as follows: systematic literature search with well-defined inclusion criteria, carefully excluding small studies, case reports and redundant studies, inclusion of high quality studies, detailed extraction of clinically useful data in terms of early and delayed AEs attributed to LAMS, rigorous evaluation of study quality, overall low to zero heterogeneity, and statistics to establish and/or refute the validity of the results of our meta-analysis.

There were few limitations to this study and are the ones expected with any meta-analysis. The included studies were not entirely representative of the general population and community practice. The studies did not uniformly follow the severity of AEs grading according to the lexicon of endoscopic AEs. The data itself were derived from a patient group with high morbidity and/or mortality and were not able to stratify our results based on patient performance characteristics. Paucity of data limited our ability to analyze the events with respect to the commercial type of stent used. More large-scale studies are needed to better compare the safety profiles of the different types of LAMS, along with cost-effectiveness. However, this estimate is still the best available estimate that may be used in counseling patients undergoing GBD with LAMS.

CONCLUSION

In conclusion, our estimated risk of LAMS-related AE with EUS-GBD is 13%, which is the lowest reported in literature thus far. The rate of early AE is 6.5%, and the risk of delayed AE is 8%. There was low to no heterogeneity in our analysis.

Supplementary materials

Supplementary information is linked to the online version of the paper on the Endoscopic Ultrasound website.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

SUPPLEMENT MATERIALS

Supplement Figure 1

Forest plot - overall bleeding

Supplement Figure 2

Forest plot - early bleeding

Supplement Figure 3

Forest plot - delayed bleeding

Supplement Figure 4

Forest plot - overall bile leak

Supplement Figure 5

Forest plot - early bile leak

Supplement Figure 6

Forest plot - delayed bile leak

Supplement Figure 7

Forest plot - stent occlusion (all delayed)

Supplement Figure 8

Forest plot - perforation (all early)

Supplement Figure 9

Forest plot - overall stent migration

Supplement Figure 10

Forest plot - early stent migration

Supplement Figure 11

Forest plot - delayed stent migration

Supplement Figure 12

Forest plot - recurrent cholangitis

Supplement Figure 13

Forest plot - death

Supplement Figure 14

Forest plot - technical success

Supplement Figure 15

Forest plot - clinical success

Supplement Figure 16

Funnel plot – all studies

REFERENCES

1. Itoi T, Binmoeller KF, Shah J, et al. Clinical evaluation of a novel lumen-apposing metal stent for endosonography-guided pancreatic pseudocyst and gallbladder drainage (with videos) Gastrointest Endosc. 2012;75:870–6. [Abstract] [Google Scholar]
2. Teoh AY, Ng EK, Chan SM, et al. Ex vivo comparison of the lumen-apposing properties of EUS-specific stents (with video) Gastrointest Endosc. 2016;84:62–8. [Abstract] [Google Scholar]
3. Yang D, Nieto JM, Siddiqui A, et al. Lumen-apposing covered self-expandable metal stents for short benign gastrointestinal strictures: A multicenter study. Endoscopy. 2017;49:327–33. [Abstract] [Google Scholar]
4. Siddiqui AA, Kowalski TE, Loren DE, et al. Fully covered self-expanding metal stents versus lumen-apposing fully covered self-expanding metal stent versus plastic stents for endoscopic drainage of pancreatic walled-off necrosis: Clinical outcomes and success. Gastrointest Endosc. 2017;85:758–65. [Abstract] [Google Scholar]
5. Dollhopf M, Larghi A, Will U, et al. EUS-guided gallbladder drainage in patients with acute cholecystitis and high surgical risk using an electrocautery-enhanced lumen-apposing metal stent device. Gastrointest Endosc. 2017;86:636–43. [Abstract] [Google Scholar]
6. Khashab MA, Bukhari M, Baron TH, et al. International multicenter comparative trial of endoscopic ultrasonography-guided gastroenterostomy versus surgical gastrojejunostomy for the treatment of malignant gastric outlet obstruction. Endosc Int Open. 2017;5:E275–81. [Europe PMC free article] [Abstract] [Google Scholar]
7. IntHout J, Ioannidis JP, Borm GF, et al. Small studies are more heterogeneous than large ones: A meta-meta-analysis. J Clin Epidemiol. 2015;68:860–9. [Abstract] [Google Scholar]
8. Adler DG, Shah J, Nieto J, Binmoeller K, Bhat Y, Taylor LJ, Siddiqui AA. Placement of lumen-apposing metal stents to drain pseudocysts and walled-off pancreatic necrosis can be safely performed on an outpatient basis: A multicenter study. Endosc Ultrasound [Epub ahead of print] [Last cited on 2019 Jan 02]. Available from: http://www.eusjournal.com/preprintarticle.asp?id=232608 . [Europe PMC free article] [Abstract]
9. Moher D, Liberati A, Tetzlaff J, et al. Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement. Ann Intern Med. 2009;151:264–9, W64. [Abstract] [Google Scholar]
10. Jang JW, Lee SS, Song TJ, et al. Endoscopic ultrasound-guided transmural and percutaneous transhepatic gallbladder drainage are comparable for acute cholecystitis. Gastroenterology. 2012;142:805–11. [Abstract] [Google Scholar]
11. Irani S, Ngamruengphong S, Teoh A, et al. Similar efficacies of endoscopic ultrasound gallbladder drainage with a lumen-apposing metal stent versus percutaneous transhepatic gallbladder drainage for acute cholecystitis. Clin Gastroenterol Hepatol. 2017;15:738–45. [Abstract] [Google Scholar]
12. Stang A. Critical evaluation of the newcastle-ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol. 2010;25:603–5. [Abstract] [Google Scholar]
13. DerSimonian R, Laird N. Meta-analysis in clinical trials. Control Clin Trials. 1986;7:177–88. [Abstract] [Google Scholar]
14. Sutton AJ, Abrams KR, Jones DR, et al. Methods for Meta-Analysis in Medical Research. New York: John Wiley & Sons Ltd; 2000. pp. 205–28. [Google Scholar]
15. Kanwal F, White D. “Systematic reviews and meta-analyses” in clinical gastroenterology and hepatology. Clin Gastroenterol Hepatol. 2012;10:1184–6. [Abstract] [Google Scholar]
16. Higgins JP, Thompson SG, Deeks JJ, et al. Measuring inconsistency in meta-analyses. BMJ. 2003;327:557–60. [Europe PMC free article] [Abstract] [Google Scholar]
17. Guyatt GH, Oxman AD, Kunz R, et al. GRADE guidelines: 7. Rating the quality of evidence – Inconsistency. J Clin Epidemiol. 2011;64:1294–302. [Abstract] [Google Scholar]
18. Higgins JP, Thompson SG, Spiegelhalter DJ. A re-evaluation of random-effects meta-analysis. J R Stat Soc Ser A Stat Soc. 2009;172:137–59. [Europe PMC free article] [Abstract] [Google Scholar]
19. Riley RD, Higgins JP, Deeks JJ. Interpretation of random effects meta-analyses. BMJ. 2011;342:d549. [Abstract] [Google Scholar]
20. Easterbrook PJ, Berlin JA, Gopalan R, et al. Publication bias in clinical research. Lancet. 1991;337:867–72. [Abstract] [Google Scholar]
21. Anderloni AA, Fugazza A, Auriemma F, et al. Su1416 EUS-guided choledochoduodenostomy using a lumen apposing metal stent for malignant distal biliary obstruction: A restrospective analysis of a single center experience. Gastrointest Endosc. 2018;87:AB347. [Google Scholar]
22. Garcia-Alonso FJ, Sanchez-Ocana R, Peñas-Herrero I, et al. Cumulative risks of stent migration and gastrointestinal bleeding in patients with lumen-apposing metal stents. Endoscopy. 2018;50:386–95. [Abstract] [Google Scholar]
23. Kunda R, Pérez-Miranda M, Will U, et al. EUS-guided choledochoduodenostomy for malignant distal biliary obstruction using a lumen-apposing fully covered metal stent after failed ERCP. Surg Endosc. 2016;30:5002–8. [Abstract] [Google Scholar]
24. Walter D, Teoh AY, Itoi T, et al. EUS-guided gall bladder drainage with a lumen-apposing metal stent: A prospective long-term evaluation. Gut. 2016;65:6–8. [Abstract] [Google Scholar]
25. Teoh AY, Chan SM, Rerknimitr R, et al. Su1386 the use of a newly developed self-approximating lumen apposing metallic stent for drainage of the gallbladder and common bile duct – A multi-centered prospective study. Gastrointestinal Endoscopy. 2018;87:AB333–4. [Google Scholar]
26. Teoh AY, Serna C, Penas I, et al. Endoscopic ultrasound-guided gallbladder drainage reduces adverse events compared with percutaneous cholecystostomy in patients who are unfit for cholecystectomy. Endoscopy. 2017;49:130–8. [Abstract] [Google Scholar]
27. Ahmed O, Ogura T, Eldahrouty A, et al. Endoscopic ultrasound-guided gallbladder drainage: Results of long-term follow-up. Saudi J Gastroenterol. 2018;24:183–8. [Europe PMC free article] [Abstract] [Google Scholar]
28. Bang JY, Navaneethan U, Hasan M, et al. Stent placement by EUS or ERCP for primary biliary decompression in pancreatic cancer: A randomized trial (with videos) Gastrointest Endosc. 2018;88:9–17. [Abstract] [Google Scholar]
29. Choi JH, Lee SS, Choi JH, et al. Long-term outcomes after endoscopic ultrasonography-guided gallbladder drainage for acute cholecystitis. Endoscopy. 2014;46:656–61. [Abstract] [Google Scholar]
30. Choi JH, Kim HW, Lee JC, et al. Percutaneous transhepatic versus EUS-guided gallbladder drainage for malignant cystic duct obstruction. Gastrointest Endosc. 2017;85:357–64. [Abstract] [Google Scholar]
31. Song TJ, Hyun YS, Lee SS, et al. Endoscopic ultrasound-guided choledochoduodenostomies with fully covered self-expandable metallic stents. World J Gastroenterol. 2012;18:4435–40. [Europe PMC free article] [Abstract] [Google Scholar]
32. Takagi W, Ogura T, Sano T, et al. EUS-guided cholecystoduodenostomy for acute cholecystitis with an anti-stent migration and anti-food impaction system; a pilot study. Therap Adv Gastroenterol. 2016;9:19–25. [Europe PMC free article] [Abstract] [Google Scholar]
33. Han D, Inamdar S, Lee CW, et al. Lumen apposing metal stents (LAMSs) for drainage of pancreatic and gallbladder collections: A meta-analysis. J Clin Gastroenterol. 2018;52:835–44. [Abstract] [Google Scholar]
34. Manta R, Mutignani M, Galloro G, et al. Endoscopic ultrasound-guided gallbladder drainage for acute cholecystitis with a lumen-apposing metal stent: A systematic review of case series. Eur J Gastroenterol Hepatol. 2018;30:695–8. [Abstract] [Google Scholar]
35. Kalva NR, Vanar V, Forcione D, et al. Efficacy and safety of lumen apposing self-expandable metal stents for EUS guided cholecystostomy: A meta-analysis and systematic review. Can J Gastroenterol Hepatol. 2018;2018:7070961. [Europe PMC free article] [Abstract] [Google Scholar]
36. Jain D, Bhandari BS, Agrawal N, et al. Endoscopic ultrasound-guided gallbladder drainage using a lumen-apposing metal stent for acute cholecystitis: A systematic review. Clin Endosc. 2018;51:450–62. [Europe PMC free article] [Abstract] [Google Scholar]

Articles from Endoscopic Ultrasound are provided here courtesy of Wolters Kluwer Health

Citations & impact 


Impact metrics

Jump to Citations

Citations of article over time

Smart citations by scite.ai
Smart citations by scite.ai include citation statements extracted from the full text of the citing article. The number of the statements may be higher than the number of citations provided by EuropePMC if one paper cites another multiple times or lower if scite has not yet processed some of the citing articles.
Explore citation contexts and check if this article has been supported or disputed.
https://scite.ai/reports/10.4103/eus.eus_63_18

Supporting
Mentioning
Contrasting
0
1
0

Article citations


Go to all (14) article citations

Data 


Data behind the article

This data has been text mined from the article, or deposited into data resources.

Similar Articles 


To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation.