Influences of Prosthesis Stem Lengths in Cementless Total Hip Arthroplasty

Article Preview

Abstract:

Stress shielding phenomenon is an important issues in considering the primary stability of the cementless hip arthroplasty. Stress shielding occurs when there is a mismatch in the elastic modulus of two materials perfectly bonded to each other, such as the prosthesis stem and the bone. In this study, influences of different prosthesis stem lengths on stress distribution in cementless THA are examined using finite element method. The calculated stress distribution is discussed with respect to stress shielding and primary stability issues in THA femur cases. Results show that similar pattern in stress distribution for intact and THA femur but differs in magnitudes. The stress level increases from the neck to the middle region and peaks at locations coinciding with the tip of the prosthesis. The maximum stress for intact femur is 55.5 MPa, THA with short stem is defined up to 112 MPa, while with medium and long stem are 204 MPa and 278 MPa, respectively.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2088-2093

Citation:

Online since:

March 2011

Export:

Price:

[1] A.N. Ohannes, M. Gregory, P.J. Ravindra, W.S. Brian and N.S. Eftekhar: A 15- yo 25- Year Follow-up Study of Primary Charnley Low-Friction Arthroplasty, The Journal of Anthroplasty, Vol. 20, No. 2 (2005), pp.162-167.

DOI: 10.1016/j.arth.2004.07.006

Google Scholar

[2] E.L. Masterson, C.A. Busch, C.P. Duncan and K. Drabu: Impaction Allografting of The Proximal Femur using A Charnley-Type Stem: A Cement Mantle Analysis, The Journal of Arthroplasty, Vol. 14, No. 1 (1999), pp.59-63.

DOI: 10.1016/s0883-5403(99)90203-6

Google Scholar

[3] A.H. Abdullah, M.N. Mohd Asri, M.S. Alias, M.N. Tamin and M.R. A Kadir: Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty, IAENG Transactions on Engineering Technologies Volume 5: Special Edition of. International MultiConference of Engineers and Computer Scientists 2010, AIP Conf. Proc. (2010).

DOI: 10.1063/1.3510578

Google Scholar

[4] Z. Lu: Finite Element Analysis of the Effects of Stem Geometry, Surface Finish and Cement Viscoelasticity on Debonding and Subsidence of Total Hip Prosthesis, PhD thesis, Faculty of the Graduate School, University of Southern California (2001).

Google Scholar

[5] H. Malchau, P. Herberts and L. Ahnieit: Prognosis of Total Hip Replacement in Sweden: Follow-up of 9267. 5 Operations Performed 1978-1990, Acta Orthop Scand, Vol. 64 (1993), pp.497-506.

DOI: 10.3109/17453679308993679

Google Scholar

[6] W.R. Taylor, E. Roland, H. Ploeg, D. Hertig, R. Klabunde, M.D. Warner, M.C. Hobatho, L. Rakotomanana and S.E. Clift: Determination of Orthotropic Bone Elastic Constants using FEA and Modal Analysis, J. Biomech (2002), pp.767-773.

DOI: 10.1016/s0021-9290(02)00022-2

Google Scholar

[7] I.A.J. Radcliffe, P. Prescott, H.S. Man and M. Taylor: Determination of Suitable Sample Sizes for Multi-Patient Based Finite Element Studies, Medical Engineering Physics 29 (2007), pp.1065-1072.

DOI: 10.1016/j.medengphy.2006.11.007

Google Scholar