Skip to main content
Log in

Core Temperature Measurement

Methods and Current Insights

  • Current Opinion
  • Published:
Sports Medicine Aims and scope Submit manuscript

Abstract

Climatic injuries, including hypothermia, hyperthermia and heat stroke, are common in many sports activities. Body core temperature (Tc) measurement for the sportsperson can influence individual performance and may help to prevent injuries. Monitoring internal body Tc accurately requires invasive methods of measurement. The mercury thermometer, most commonly used to measure oral temperature (Toral), has been almost exclusively the only instrument for measuring Tc since the 18th century. Rectal (Tre) and oesophageal temperatures (Toes) have been the most preferred measurement sites employed in thermoregulatory investigations. However, these measurement sites (Tre, Toes, Toral), and the methods used to measure Tc at these sites, are not convenient. Toral measurements are not always possible or accurate. Toes is undesirable because of the difficulty of inserting the thermistor, irritation to nasal passages and general subject discomfort. Tre is not suitable under many circumstances as it is labour intensive and has a prolonged response time. However, Tre remains the most accurately available method for monitoring Tc in thermal illness that occurs during sports activities. In addition, Tre and Toes require wire connections between the thermistor and the monitoring device. The purpose of this paper is to review the various existing methods of Tc measurements in order to focus on the breakthrough needed for a simple, noninvasive, universally used device for Tc measurement which is essential for preventing climatic injuries during sports events.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Hensel H. Thermal comfort in man, thermoreception and temperature regulation. New York: Academic Press, 1981

    Google Scholar 

  2. Ring EFJ. Progress in the measurement of human body temperature. IEEE Eng Med Biol Mag 1998; 17: 19–24

    Article  PubMed  CAS  Google Scholar 

  3. Deuteronomy 28.22. The Holy Scriptures of the Old Testament, Hebrew and English. London: British and Foreign Bible Society, 1996: 325

    Google Scholar 

  4. Wunderlich C. On the temperature in disease: a manual of medical thermometry. Translated by W Bathurst Woodman. London: New Sydenham Society, 1871

    Google Scholar 

  5. Cetas TC. Thermometers. In: Mackowiak PA, editor. Fever: basic mechanisms and management. Philadelphia (PA): Lippincott-Raven Publishers, 1997: 11–34

    Google Scholar 

  6. Cattaneo CG, Frank SM, Hesel TW, et al. The accuracy and precision of body temperature monitoring methods during regional and general anesthesia. Anesth Analg 2000; 90: 938–45

    Article  PubMed  CAS  Google Scholar 

  7. Amoateng-Adjepong Y, Del Mundo J, Manthous CA. Accuracy of an infrared tympanic thermometer. Chest 1999; 115: 1002–5

    Article  PubMed  CAS  Google Scholar 

  8. Briner Jr WW. Tympanic membrane vs rectal temperature measurement in marathon runners [letter]. J Am Med Assoc 1996; 276: 194

    Article  Google Scholar 

  9. Hooker EA, Houston H. Screening for fever in adult emergency department: oral vs tympanic thermometry. South Med J 1996; 89: 230–4

    Article  PubMed  CAS  Google Scholar 

  10. Sawka MN, Wenger CB. Physiologic responses to acute exercise heat stress. In: Pandolf KB, Sawka MN, Gonzalez RR, editors. Human performance physiology and environmental medicine at terrestrial extremes. Indianapolis (IN): Benchmark Press, 1998: 97–151

    Google Scholar 

  11. Stuart MC, Lee SMC, Williams WJ, et al. Core temperature measurement during supine exercise: esophageal, rectal and intestinal temperature. Aviat Space Environ Med 2000; 71: 939–45 12. Brengelmann GL. Dilemma of body temperature measurement. In: Shiraki K, Yousef MK, editors. Man in stressful environments: thermal and work physiology. Springfield (IL): Charles C. Thomas, 1987: 5–22

    Google Scholar 

  12. Brengelmann GL. Dilemma of body temperature measurement. In: Shiraki K, Yousef MK, editors. Man in stressful environments: thermal and work physiology. Springfield (IL): Charles C. Thomas, 1987: 5–22

    Google Scholar 

Download references

Acknowledgements

The authors have provided no information on sources of funding or on conflicts of interest directly relevant to the content of this review.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Daniel S. Moran.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Moran, D.S., Mendal, L. Core Temperature Measurement. Sports Med 32, 879–885 (2002). https://doi.org/10.2165/00007256-200232140-00001

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2165/00007256-200232140-00001

Keywords

Navigation