Abstract
Based on a new electrogenerated chemiluminescence (ECL) analytical idea, this paper explains a sensitive and selective flow-injection ECL method using luminol for the determination of isoniazid, based on the sensitizing effect of isoniazid for the weak ECL emission of electrochemically oxidized luminol. Under the optimum experimental conditions, the relative ECL intensity was linear with isoniazid concentration in the range of 4.0 × 10–8 mol/L to 8.0 × 10–6 mol/L and with a detecting limit of 2.8 × 10–8 mol/L.
Similar content being viewed by others
References
N. M. A. Mahfouz and K. M. Emara, Talanta, 1993, 40, 1023.
C. S. P. Sastry, S. G. Rao, P. Y. Naidu, and K. R. Srinivas, Anal. Lett., 1998, 31, 263.
J. A. Garcia-bautista, J. V. Garcia Mateo, and J. M. Calatayud, Anal. Lett., 1998, 31, 1209.
J. A. Tong, X. J. Dang, and L. H. Li, Electroanalysis, 1997, 9, 165.
S. T. Sulainman and Y. O. Hameed, Anal. Chim. Acta, 1988, 206, 379.
F. Zhao, Y. Y. Wu, Z. Gen, and H. X. Wang, Fenxihuaxue (Chinese), 1997, 25, 927.
S. A. Halvatzis, M. M. Timotheou-Potamia, and A. C. Calokerinos, Analyst, 1990, 115, 1229.
J. Huang, C. Zhang, and Z. Zhang, Fresenius J. Anal. Chem., 1999, 363, 126.
M. I. Davies, Anal. Chim. Acta, 1999, 379, 227.
X. Paez, P. Rade, S. Tucci, N. Rodriguex, and L. Hernandez, J. Chromatogr. A, 1996, 735(1–2), 263.
M. D. Telting, O. D. Scott, and E. C. Lunte, Anal. Chem., 1992, 64, 806.
X. Paez and L. Hernandez, Life Sci., 1997, 61, 847.
A. W. Knight and G. M. Greenway, Analyst, 1994, 119, 879.
I. Rubinstein, C. R. Martin, and A. J. Bard, Anal. Chem., 1983, 55, 1580.
A. W. Knight, Tr. Anal. Chem., 1999, 18(1), 47.
M. Sato and T. Yamada, Anal. Sci., 1986, 2, 529.
A. W. Knight and G. M. Greenway, Analyst, 1994, 120, 2543.
R. Wilson and D. J. Schiffrin, Anal. Chem., 1996, 68, 1254.
Y. Wang and E. S. Yeung, Anal. Chim. Acta, 1992, 266, 295.
T. A. Nieman, Microchim. Acta, 1988, 3, 239.
J. P. Preston and T. A. Nieman, Anal. Chim., 1996, 68, 966.
G. B. Xu and S. J. Dong, Electroanalysis, 1999, 11, 1180.
S. K. Poznyak and A. I. Kulak, Talanta, 1996, 43, 1607.
C. A. Marquette and L. J. Blum, Anal. Chim. Acta, 1999, 381, 1.
V. C. Tsafack, C. A. Marquette, B. Leca, and L. J. Blum, Analyst, 2000, 125, 151.
K. E. Haapakka, Anal. Chim. Acta, 1982, 139, 229.
K. E. Haapakka and J. J. Kankare, Anal. Chim. Acta, 1980, 118, 333.
J. An and Q. Yao, Fenxi Huaxue (Chinese), 1990, 18, 867.
J. E. Vitt, D. C. Johnscn, and R. C. Engstrom, J. Electrochem. Soc., 1991, 138, 1637.
S. Sakura, Anal. Chim. Acta, 1992, 262, 49.
G. N. Chen, R. E. Lin, H. S. Zhuang, Z. F. Zhao, X. Q. Xue, and F. Zhang, Anal. Chim. Acta, 1998, 375, 269.
E. H. White and D. F. Roswell, “Chemi- and Bioluminescence”, ed. J. G. Burr, 1985, Marcel Dekker, New York, H.215.
Y. Huang, Z. Zhang, J. Lv, and H. Cheng, Anal. Chim. Acta, 2000, 419, 175.
I. Jacobson, M. Sandberg, and A. Hamberger, J. Neurosci. Methods, 1985, 5, 263.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zheng, X., Guo, Z. & Zhang, Z. Flow-Injection Electrogenerated Chemiluminescence Determination of Isoniazid Using Luminol. ANAL. SCI. 17, 1095–1099 (2001). https://doi.org/10.2116/analsci.17.1095
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.17.1095