Abstract
This paper investigates the feasibility of using the small-dimension break-off test for evaluation of the bond quality at the interface between steel bar and concrete. Experimental studies were performed on bar-type concrete specimens and reinforced concrete beams. Twelve bar-type concrete specimens containing plain and deformed steel bars with different diameters were used to develop the relationship between the break-off moment and the adhesive strength at the steel bar/concrete interface. Subsequently, three reinforced concrete beams containing normal reinforcing bars, epoxy-coated reinforcing bars, and bars smeared with oil to simulate various adhesive conditions at the bar/concrete interface were used to study how the break-off moment and the bond strength were affected by the different adhesive conditions. In addition, two beam specimens containing normal reinforcing bars were vibrated severely on a self-made shaking table shortly after initial setting of concrete to simulate the bond damage in fresh reinforced concrete beams due to unexpected vibration or impact. Experimental results show that the effective break-off moment has a good correlation with the adhesive strength at the interface between steel bar and concrete. The break-off moment increases with an increase in bond strength. It is demonstrated that the small-dimension break-off test is capable of evaluating damage at the steel bar/concrete interface.
Similar content being viewed by others
References
Chinn J, Ferguson PM, Thompson JN (1955) Lapped splices in R.C. beams. ACI J 52(2):201–214
Park P, Paulay T (1975) Reinforced concrete structures. Wiley, New York
Ezeldin AS, Balaguru PN (1989) Bond behavior of normal and high-strength fiber reinforced concrete. ACI Mater J 86(5):515–524
Treece RA, Jirsa JO (1989) Bond strength of epoxy-coated reinforcing bars. ACI Mater J 86(2):167–174
Hwang SJ, Lee YY, Lee CS (1994) Effect of silica fume on the splice strength of deformed bars of high-performance concrete. ACI Struct J 91(3):294–302
Cairns J, Jones K (1995) Influence of rib geometry on strength of lapped joints: an experimental and analytical study. Mag Concr Res 47(172):253–262
Amleh L, Mirza S (1999) Corrosion influence on bond between steel and concrete. ACI Struct J 96(3):415–423
Fang C, Lundgren K, Plos M, Gylltoft K (2006) Bond behaviour of corroded reinforcing steel bars in concrete. Cem Concr Res 36:1931–1938
Lin YF, Lin Y, Tsai BY (2004) Evaluating bond quality at the interface between reinforcing bars and concrete using the impact-echo method. ACI Mater J 101(2):154–161
BS 1881-Part 207 (1992) Recommendations for the assessment of concrete strength by near-to-surface tests. BSI Group, London, UK
ASTM C 1150 (1992) Standard test method for the break-off number of concrete, vol 04.02. Annual Book of ASTM Standards
Olsen NH (1990) The strength of overlapped deformed tensile reinforcement splices in high strength concrete. Report Serie R, No. 234, Department of Structural Engineering, Technical University of Denmark, 193 pp
Hwang SJ, Leu YR, Hwang HL (1996) Tensile bond strengths of deformed bars of high-strength concrete. ACI Struct J 93(1):11–20
ACI 228.1R-03 report (2003) In-place methods to estimate concrete strength. American Concrete Institute, 44 pp
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lin, Y., Lin, YF. & Hsiao, C. Evaluation of bond quality at the interface between steel bar and concrete using the small-dimension break-off test. Mater Struct 43, 583–595 (2010). https://doi.org/10.1617/s11527-009-9514-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1617/s11527-009-9514-y