Muscle fatigue detection through wearable sensors: a comparative study using the myo armband

Authors Info & Claims
Published:25 September 2017Publication History

ABSTRACT

Novel wearable systems allow the measure of very complex physiological phenomena extending their capabilities and maintaining their non-invasiveness. A good example of this is the use of superficial electrodes for recording electromyography signals (also called superficial electromyography- sEMG) which can reveal information regarding muscle force and fatigue. Aiming at demonstrate the accuracy of a commercial grade wearable system for sEMG, the Myo Armband for fatigue measurement, we carried out a comparative study. 3 subjects were used under a standard protocol for fatigue detection using two different sensors: a Base ground-truth sEMG sensor, and the commercial wristband Myo, both connected in the biceps brachii. Time and frequency domain parameters were compared using an ANOVA test and a correlation analysis. Results showed a median correlation for the three subjects between 0.4 and 0.6 between the Base Sensor and the Myo Armband signals exposing significant differences p <0.05 for all three cases. The biomarkers of the sEMG signal of both sensors were consistent research found in the literature. Novel wearables sensors can be used in medical scenarios where high accuracy is not a requirement, instead, non-invasiveness can provide ubiquity for rehabilitation treatments as well as a continuous signal recording and data logging processes.

References

  1. Fairclough, S. and K. Gilleade. 2014. Advances in physiological computing. Springer Science & Business Media. Google ScholarGoogle ScholarDigital LibraryDigital Library
  2. Merletti, R. and D. Farina. 2016. Surface electromyography: physiology, engineering and applications. John Wiley & Sons.Google ScholarGoogle Scholar
  3. Montoya, M ; Muñoz, J and Henao, Oscar. 2015. Surface EMG based muscle fatigue detection using a low cost wearable sensor and amplitude frequency analysis. Actas de Ingenieria. Vol 1: p 29--33Google ScholarGoogle Scholar

Index Terms

  1. Muscle fatigue detection through wearable sensors: a comparative study using the myo armband

      Recommendations

      Comments

      Login options

      Check if you have access through your login credentials or your institution to get full access on this article.

      Sign in
      • Published in

        cover image ACM Other conferences
        Interacción '17: Proceedings of the XVIII International Conference on Human Computer Interaction
        September 2017
        268 pages
        ISBN:9781450352291
        DOI:10.1145/3123818

        Copyright © 2017 ACM

        Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

        Publisher

        Association for Computing Machinery

        New York, NY, United States

        Publication History

        • Published: 25 September 2017

        Permissions

        Request permissions about this article.

        Request Permissions

        Check for updates

        Qualifiers

        • research-article

        Acceptance Rates

        Overall Acceptance Rate109of163submissions,67%

      PDF Format

      View or Download as a PDF file.

      PDF

      eReader

      View online with eReader.

      eReader