Abstract
A polypyrrole electrode with ferrocene mediator is prepared and its sensitivity to hydrogen peroxide is investigated. The polypyrrole is deposited upon a 0.5 cm2 Pt plate by the polymerization of pyrrole by scanning the electrode potential between 0.0 and 0.9 V at a scan rate of 50 mV/s. The platinum/polypyrrole-ferrocene (Pt/PPy-Fc) electrode is prepared by adding ferrocene to the coverage medium. The electrode’s sensitivity to hydrogen peroxide is investigated at room temperature using 0.025 M phosphate buffer at pH 7. The working potential is 0.7 V, the concentrations of pyrrole and ferrocene are 0.2 M and 10 mM. Polypyrrole was coated on the electrode surface within 26 cycles.
Similar content being viewed by others
References
Choi, M.M.F. and Yiv, T.P., Enzyme Microb. Techonol., 2004, vol. 34, p. 41.
Pei, J. and Li, X., Anal. Chim. Acta, 2000, vol. 414, p. 205.
Laudet, E., Botting, N.P., Crayston, J.A., and Dale, N., Biosens. Bioelectron., 2003, vol. 18, p. 43.
Arai, G., Takahashi, S., and Yasumori, I., J. Electroanal. Chem., 1996, vol. 410, p. 173.
Tian, F., Xu, B., Zhu, L., and Zhu, G., Anal. Chim. Acta, 2001, vol. 443, p. 9.
Nakabayashi, Y. and Yoshikawa, H., Anal. Sci., 2000, vol. 16, p. 609.
Razola, S., Ruiz, B.L., Diez, N.M., Mark, H.B., Jr., and Kauffman, J-M., Biosens. Bioelectron., 2002, vol. 17, p. 921.
Campanella, L., Favera, G., Glancola, D., and Tomassetti, M., J. Pharm. Biomed. Anal., 2003, vol. 32, p. 737.
Kim, E.J., Haruyama, T., Yanagida, Y., Kobatake, E., and Aizawa, M., Anal. Chim. Acta, 1999, vol. 394, p. 225.
Gros, P., Durliat, H., and Comtat, M., Electrochim. Acta, 2000, vol. 46, p. 643.
Umona, M. and Waller, J., Anal. Chem., 1986, vol. 58, p. 2979.
Selampinar, F., Akbulut, V., Özden, M.Y., and Toppare, L., Biomaterials, 1997, vol. 18, p. 1163.
Gerard, M., Chaubey, A., and Malhotra, B.D., Biosens. Bioelectron., 2002, vol. 17, p. 345.
Telefoncu, A., Biyosensörler, İzmir: Kuşadasi, 1999.
Chaubey, A. and Malhotra, B.D., Biosens. Bioelectron., 2002, vol. 17, p. 441.
Garcia, C.A.B., Neto, G.O., and Kubota, L.T., Anal. Chim. Acta, 1998, vol. 374, p. 201.
Zhao, H., Yuan, Y., Adelojue, S., and Wallace, G.G., Anal. Chim. Acta, 2002, vol. 472, p. 113.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published in Russian in Elektrokhimiya, 2006, Vol. 42, No. 2, pp. 160–164.
The text was submitted by the authors in English.
Rights and permissions
About this article
Cite this article
Arslan, F., Yaşar, A. & Kiliç, E. Preparation of Pt/polypyrrole-ferrocene hydrogen peroxide sensitive electrode for the use as a biosensor. Russ J Electrochem 42, 137–140 (2006). https://doi.org/10.1134/S1023193506020042
Received:
Issue Date:
DOI: https://doi.org/10.1134/S1023193506020042