15 June 1984 Imaging And Noise Limitations Of Cesium Iodide X-Ray Image Intensifiers
J A. Rowlands, K. W Taylor, H N Cardinal
Author Affiliations +
Proceedings Volume 0454, Application of Optical Instrumentation in Medicine XII; (1984) https://doi.org/10.1117/12.939356
Event: Application of Optical Instrumentation in Medicine XII, 1984, San Diego, United States
Abstract
The conventional x-ray image intensifier (XRII) has developed from an aid for fluoroscopy, where resolution is poor and noise high, through XRII photofluorography, where high resolution is needed and noise is moderate, to digital subtraction angiography, where resolution is moderate, noise must be very low and imaging capability must be pushed to its fundamental limits. These limits are not well understood for XRII. A better knowledge of the fundamental properties of the XRII will enable us to understand and determine these limits. We have measured detective quantum efficiency (DQE), spatial modulation transfer function (MTF), spatial noise spectra and temporal frequency response using monoenergetic x-rays derived from x-ray fluorescence. The results can be accounted for by an analysis based on the physical structure and operation of the XRII. Detailed measurements on every tube are unnecessary provided that the salient parameters (thickness, separation, and radii of curvature of the CsI phosphor layer, substrate and input window, MTF and temporal frequency response) are given by the manufacturer. With this fundamental knowledge it becomes possible to understand the limits of existing XRII and to explore the possibility of improving the images by digital enhancement, by better choice of incident x-ray spectra and by modifications of the XRII themselves. This will be illustrated by application to the case of digital subtraction angiography.
© (1984) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
J A. Rowlands, K. W Taylor, and H N Cardinal "Imaging And Noise Limitations Of Cesium Iodide X-Ray Image Intensifiers", Proc. SPIE 0454, Application of Optical Instrumentation in Medicine XII, (15 June 1984); https://doi.org/10.1117/12.939356
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Modulation transfer functions

X-rays

Electrons

Absorption

X-ray imaging

Light scattering

Scattering

Back to Top