Calorimetric Determination of the Half-Life of Polonium-210

J. F. Eichelberger, K. C. Jordan, S. R. Orr, and J. R. Parks
Phys. Rev. 96, 719 – Published 1 November 1954
PDFExport Citation

Abstract

Six determinations have been made of the half-life of polonium with four different steady-state, resistance-bridge calorimeters and five different samples of polonium. These six values of the half-life have been weighted and combined to give a grand-mean value of the half-life of 138.4005±0.0051 days (internal consistency) or ±0.0058 day (external consistency).

  • Received 14 May 1953

DOI:https://doi.org/10.1103/PhysRev.96.719

©1954 American Physical Society

Authors & Affiliations

J. F. Eichelberger, K. C. Jordan, S. R. Orr, and J. R. Parks*

  • Mound Laboratory, Monsanto Chemical Company, Miamisburg, Ohio

  • *Mound Laboratory is operated by Monsanto Chemical Company for the U. S. Atomic Energy Commission.