Issue 13, 2019

A ratiometric electrochemical sensor for multiplex detection of cancer biomarkers using bismuth as an internal reference and metal sulfide nanoparticles as signal tags

Abstract

Ratiometric electrochemical sensors can provide a relatively accurate analysis of target analytes due to their self-calibration function. Herein, we report a simple ratiometric strategy for achieving the electrochemical detection of Cd(II), Hg(II), Pb(II) and Zn(II), as well as multiple cancer biomarkers by using metal sulfide nanoparticles as signal tags. A conductive polymer film of poly(2-amino terephthalic acid) (ATA) was electrochemically produced on a glassy carbon electrode (GCE) and doped with carbon nanotubes (CNTs) and mercaptosuccinic acid (MSA). Using Bi(III) as an enhancer and internal reference in anodic stripping voltammetry, the MSA-CNT-ATA/GCE exhibited sensitive and distinguishable voltammetric responses to Cd(II), Hg(II), Pb(II) and Zn(II), with detection limits of 0.13, 0.49, 0.16 and 0.089 μg L−1, respectively. By using CdS, HgS, PbS and ZnS labeled secondary antibodies as the signal tags, alpha-fetoprotein, carbohydrate antigen 19–9, carbohydrate antigen 125, and carcinoembryonic antigen were determined simultaneously according to the amounts of metal sulfide in the sandwich-type complexes, with detection limits of 0.11 pg mL−1, 0.68 mU mL−1, 1.4 mU mL−1 and 0.23 pg mL−1, respectively. This ratiometric approach has a wide scope in the electrochemical detection of heavy metal ions as well as immunoassays with metal ions serving as signal tags.

Graphical abstract: A ratiometric electrochemical sensor for multiplex detection of cancer biomarkers using bismuth as an internal reference and metal sulfide nanoparticles as signal tags

Supplementary files

Article information

Article type
Paper
Submitted
30 Apr 2019
Accepted
23 May 2019
First published
24 May 2019

Analyst, 2019,144, 4073-4080

A ratiometric electrochemical sensor for multiplex detection of cancer biomarkers using bismuth as an internal reference and metal sulfide nanoparticles as signal tags

L. Yu, X. Cui, H. Li, J. Lu, Q. Kang and D. Shen, Analyst, 2019, 144, 4073 DOI: 10.1039/C9AN00775J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements