Abstract

The push-out test of three types of biomaterials: carbon fibre-reinforced carbon (CFRC), hydroxyapatite (HA), and surgical steel (SS) implanted into rabbits’ femurs was carried out. Hydroxyapatite was used as a positive control (good fixation expected in bone) and surgical steel was a negative one (potentially no fixation in bone). Regeneration of bone in contact with all implants was found three months after implantation. The shear strength between CFRC implants and bone was lower than with the HA implants and higher than the shear strength between the surgical steel and bone. Compressive strength of CFRC implants removed after the observation period was significantly lower than the compressive strength of non-implanted samples. It is concluded that the mechanical bonding between the CFRC implants and host tissues exists 3 months after intrabone implantation and is accompanied by a decrease of the strength of implants.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P. CHRISTEL and L. CLAES, in “High performance biomaterials a comprehensive guide to medical and pharmaceutical applications”, edited by M. Szycher (Technomic Publishing Company, Lancaster, 1991) p. 499.

    Google Scholar 

  2. D. ADAMS, D. F. WILLIAMS and J. HILL, J. Biomed. Mater. Res. 12 (1978) 35.

    Google Scholar 

  3. L. PODOSHIN, R. H. NODAR, G. B. HUGHES, T. BAUER, J. D. HAYES, M. FRADIS, J. BOSS and L. RAMSEY, Amer. J. Otol. 9 (1988) 366.

    Google Scholar 

  4. Y. SHONO, P. C. Mc AFEE, B. W. CUNNINGHAM and J. W. BRANTIGAN, J. Bone Joint. Surg. Amer. 75 (1993) 1674.

    Google Scholar 

  5. C. L. TIAN, V. J. HETHERINGTON and S. REED, J. Foot Ankle 32(5) (1993) 490.

    Google Scholar 

  6. F. VALLANA, E. PASQIUNO, S. RINALDI, M. GALLONI, A. M. GATTI, F. MODICA and A. BENECH, Ceramics Int. 19 (1993) 169.

    Google Scholar 

  7. K. HAYASHI, T. INADOME, H. TSUMURA, Y. NAKASHIMA and Y. SUKOIOKA, Biomaterials 15 (1994) 1187.

    Google Scholar 

  8. T. INADOME, K. HAYASHI, Y. NAKASHIMA, H. TSUMURA and Y. SUGIOKA, J. Biomed. Mater. Res. 29 (1995) 19.

    Google Scholar 

  9. H. KIEFER, L. CLAES, C. BURRI and K. KUGLMEIER, in “Biological and biomechanical performance of biomaterials”, edited by P. Christel, A. Meunier and A. J. C. Lee (Elsevier Science Publishers B.V., Amsterdam, 1986) p. 471.

    Google Scholar 

  10. K. SØBALLE, Acta Orthop. Scand. 64(Suppl 255) (1993) 1.

    Google Scholar 

  11. J. CHŁOPEK, S. BŁAŻEWICZ, Carbon 29 (1991) 127.

    Google Scholar 

  12. M. LEWANDOWSKA-SZUMIEŁ, J. KOMENDER, D. KUDELSKA and M. MAZUR, in “Animal alternatives, welfare and ethics”, edited by L. F. M. van Zutphen and M. Balls (Elsevier Science Publishers B.V., Amsterdam, 1997) in press.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

LEWANDOWSKA-SZUMIEŁ , M., KOMENDER , J., GORECKI , A. et al. Fixation of carbon fibre-reinforced carbon composite implanted into bone. Journal of Materials Science: Materials in Medicine 8, 485–488 (1997). https://doi.org/10.1023/A:1018526226382

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1018526226382

Keywords

Navigation