Original contribution
A 40–100 MHz B-scan ultrasound backscatter microscope for skin imaging

https://doi.org/10.1016/0301-5629(94)00083-2Get rights and content

Abstract

There is a growing interest in high resolution, subsurface imaging of cutaneous tissues using higher frequency ultrasound, and several commercial systems have been developed recently which operate at 20 MHz. Some of the possible applications of higher frequency skin imaging include tumour staging, boundary definition, and studies of the response of tumours to therapy, investigations of inflammatory skin conditions such as psoriasis and eczema, and basic studies of skin aging, sun damage and the effects of irritants. Investigation of these areas is quite new, and the role of ultrasound skin imaging is continuing to evolve. Lateral resolution in the 20 MHz imaging systems ranges from 200 to 300 μm, which limits imaging applications to cutaneous structures which are relatively large in size. In this paper, a real-time ultrasound backscatter microscope (UBM) for skin imaging is described which operates in the 40–100 MHz range, providing axial resolution between 17 and 30 μm and lateral resolution between 33 and 94 μm. This improvement in resolution over current skin ultrasound systems should prove useful in determining the margins of small skin lesions, and in obtaining more precise, in vivo skin thickness measurements to characterize nonmalignant skin disease. Example images of normal skin, seborrhoeic keratosis and malignant melanoma illustrate the imaging potential of this system.

References (19)

There are more references available in the full text version of this article.

Cited by (176)

  • Nonlinear ultrasonic testing and data analytics for damage characterization: A review

    2021, Measurement: Journal of the International Measurement Confederation
    Citation Excerpt :

    A single-point measurement can only inspect the specimen along the wave propagation path. To cover all areas of the specimen, scan methods including A-Scan [73], B-Scan [74], and C-Scan [75] are developed. As shown in Fig. 8, the A-scan shows the relation of the signal strength and the time-of-flight (ToF) of the received ultrasonic waves.

  • Diagnostics of skin features through 3D skin mapping based on electro-controlled deposition of conducting polymers onto metal-sebum modified surfaces and their possible applications in skin treatment

    2021, Analytica Chimica Acta
    Citation Excerpt :

    Besides the optical methods, other techniques such as ultrasound imaging provide 3D images, but it is more popular for its B-mode that provide 2D images of organs. In fact, it has the ability to generate images with resolution of 200–300 μm [16,17]. It is also used to characterize skin lesions [18] and evaluate their response to treatment [19].

  • Ultrasound

    2021, Molecular Imaging: Principles and Practice
  • SNR improvement and range side lobe suppression in Golay-encoded Doppler detection for ultrasound high-frequency swept-scan imaging system

    2018, Biomedical Signal Processing and Control
    Citation Excerpt :

    Ultrasound high-frequency (>20 MHz) imaging system is capable of portraying fine anatomy with high image resolution and has exhibited its potential in applications of small animal pre-clinical imaging, dermatology and ophthalmology [1–6].

  • Quantitative sonography of basal cell carcinoma

    2015, Ultrasound in Medicine and Biology
View all citing articles on Scopus