PaperIntraocular PMMA lenses modified with surface-immobilized heparin: evaluation of biocompatibility in vitro and in vivo
References (13)
Biomicroscopy of surface deposits resembling foreign-body giant cells on implanted intraocular lenses
Am. J. Ophthalmol.
(1985)- et al.
Morphology of pseudophakic precipitates on intraocular lenses removed from human patients
Am. Intra-Ocular Lens Implant Soc. J.
(1985) - et al.
Complications of intraocular lenses. A historical and histopathological review
Surv. Ophthalmol.
(1984) Cythopathology of intraocular lens implantation
Ophthalmology
(1985)- et al.
Astrocytic development in fetal parietal cortex grafted to cerebral and cerebellar cortex of immature rats
Dev. Brain Res.
(1983) - et al.
Determination of platelet adhesion to polyethylene and heparinized surfaces with the aid of bioluminescence and 51chromium labelled platelets
Thromb. Res.
(1977)
Cited by (104)
Long-term In Vivo Stability of Posterior Chamber Phakic Intraocular Lens: Properties and Light Transmission Characteristics of Explants
2020, American Journal of OphthalmologyCitation Excerpt :These are well-known materials to which the immune system of the living host hardly reacts. In the 1980s, it was determined that coating the surface of a lens with another substance reduced the host's response to apIOLs.19 Furthermore, a soft contact lens made by copolymerizing methacrylate with collagen was commercially available.
Synthetic Biomaterial for Regenerative Medicine Applications
2017, Kidney Transplantation, Bioengineering, and Regeneration: Kidney Transplantation in the Regenerative Medicine EraLaser-triggered intraocular implant to induce photodynamic therapy for posterior capsule opacification prevention
2016, International Journal of PharmaceuticsCitation Excerpt :Co., Ltd (Changchun, People’s Republic of China). Preparation method of ICG-IOL was similar to that of modifying IOLs with heparin (Larm et al., 1983; Larsson et al., 1989). Briefly, IOLs were first sonicated in a bath of surfactant solution for 15 min, and then in double distilled water for another 15 min.
Effect of heparin coating of a foldable intraocular lens on inflammation and capsular bag performance after cataract surgery
2013, Journal of Cataract and Refractive SurgeryCitation Excerpt :In this study, heparin-coated foldable acrylic IOLs did not show any benefit over the same IOL without heparin coating in terms of postoperative inflammation in high-risk patients. This finding is contrary to results in older studies in which HSM PMMA IOLs were used and found to effectively reduce postoperative inflammation2,3,6,23–28 because of the anticoagulant and antiinflammatory effects of heparin.20–22 But, when HSM PMMA IOLs were compared with uncoated foldable acrylic IOLs, no significant differences in flare were found.36–38
Diamond like carbon films as a protective surface on PMMA for biomedical applications
2010, Surface and Coatings TechnologyCitation Excerpt :The life span of PMMA prostheses will also increase by the DLC coating. Extensive research has been carried out on the biocompatible study of PMMA and DLC coatings, separately [2–5,12,13,18–20]. There are very few reports on the detailed study of biocompatibility of DLC coated PMMA [8,9].
Polymers in modern ophthalmic implants - Historical background and recent advances
2010, Materials Science and Engineering R: Reports