Abstract
Purpose
Simple displaced transverse olecranon fractures are traditionally managed operatively with a tension band wire device (TBW). We compared clinical outcomes, morbidity and the cost of treatment of TBW versus pre-countered low-profile locking plates for the treatment of Mayo 2A fractures.
Patient and methods
All olecranon fractures admitted to our unit between 2008 and 2014 were identified (n = 129). Patient notes and radiographs were studied from presentation to final follow-up. Patient outcomes were recorded using the QuickDASH (Disabilities of Arm, Shoulder and Hand) score. Patient demographics and nature of complications were recorded as were the rate and nature of any repeat operation.
Results
Eighty-nine patients had Mayo 2A fractures (69%). Sixty-four underwent TBW (n = 48) or locking plate fixation (n = 16). The mean ages of both groups were similar at 57 (15–93) and 60 (22–80), respectively. In the TBW group, the mean post-injury QuickDASH was 12.9, compared with 15.0 for the locking plate group. There was no statistically significant difference between the outcomes for either group. Nineteen of the 48 TBW patients had complications (39.6%). Sixteen of the 48 TBW patients had reoperations (33.3%). In particular, we would highlight that 13 (27.1%) of patients treated with TBW underwent subsequent removal of metalwork for hardware irritation. There were no complications and or reoperations in the 16 patients who received locking plate fixation. Both complication and reoperation rates were statistically significantly different. Despite being initially more expensive, when the cost of reoperation for TBW group was included, locking plates were found to be on average £236.33 less per patient than for TBW.
Conclusions
We suggest that locking plates are superior to TBW concerning post-operative morbidity, reoperation rate and cost for Mayo 2A fractures in contrast to previous articles.
Level of evidence
Therapeutic study, III.
Similar content being viewed by others
References
Rommens PM, Kuchle R, Schneider RU, Reuter M (2004) Olecranon fractures in adults: factors influencing outcome. Injury 35:1149–1157
Morrey BF (1995) Current concepts in the treatment of fractures of the radial head, the olecranon and the coronoid. J Bone Jt Surg 77A:316–327
Weber BG, Vasey H (1963) Osteosynthesis in olecranon fractures. Z Unfallmed Berufskr 56:90–96
Schliemann B, Raschke MJ, Groene P, Weimann A, Wähnert D, Lenschow S, Kösters C (2014) Comparison of tension band wiring and precontoured locking compression plate fixation in Mayo type IIA olecranon fractures. Acta Orthop Belg 80(1):106–111
Tarallo L, Mugnai R, Adani R et al (2014) Simple and comminuted displaced olecranon fractures: a clinical comparison between tension band wiring and plate fixation techniques. Arch Orthop Trauma Surg 134:1107–1114
DelSole EM, Pean CA, Tejwani NC, Egol KA (2016) Outcome after olecranon fracture repair: Does construct type matter? Eur J Orthop Surg Traumatol 26(2):153–159
Chalidis BE, Sachinis NC, Samoladas EP et al (2008) Is tension band wiring technique the ‘‘gold standard’’ for the treatment of olecranon fractures? A long term functional outcome study. J Orthop Surg Res 3:9
Claessen FM, Braun Y, Peters RM, Dyer G, Doornberg JN, Ring D (2016) Factors associated with reoperation after fixation of displaced olecranon fractures. Clin Orthop Relat Res 474(1):193–200
Candal-Couto JJ, Williams JR, Sanderson PL (2005) Impaired forearm rotation after tension-band-wiring fixation of olecranon fractures: evaluation of the transcortical K-wire technique. J Orthop Trauma 19(7):480–482
Catalano LW 3rd, Crivello K, Lafer MP, Chia B, Barron OA, Glickel SZ (2011) Potential dangers of tension band wiring of olecranon fractures: an anatomic study. J Hand Surg Am 36(10):1659–1662
Baecher N, Edwards S (2013) Olecranon fractures. J Hand Surg Am 38(3):593–604
Ricci WM (2015) Use of locking plates in orthopaedic trauma surgery. JBJS Rev 3(3):1–11
Kennedy CA, Beaton DE, Solway S, McConnell S, Bombardier C (2011) Disabilities of the arm, shoulder and hand (DASH). The DASH and QuickDASH outcome measure user’s manual, 3rd edn. Institute for Work & Health, Toronto
Wilson J, Bajwa A, Kamath V et al (2011) Biomechanical comparison of interfragmentary compression in transverse fractures of the olecranon. J Bone Joint Surg Br 93(2):245–250
Hutchinson DT, Horwitz DS, Ha G et al (2003) Cyclic loading of olecranon fracture fixation constructs. J Bone Joint Surg Am 85(5):831–837
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Rights and permissions
About this article
Cite this article
Powell, A.J., Farhan-Alanie, O.M. & McGraw, I.W.W. Tension band wiring versus locking plate fixation for simple, two-part Mayo 2A olecranon fractures: a comparison of post-operative outcomes, complications, reoperations and economics. Musculoskelet Surg 103, 155–160 (2019). https://doi.org/10.1007/s12306-018-0556-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12306-018-0556-6