Skip to main content
Log in

Aortic Counterpulsation: C-Pulse and Other Devices for Cardiac Support

  • Published:
Journal of Cardiovascular Translational Research Aims and scope Submit manuscript

Abstract

Heart failure is the leading cause of hospitalization in the USA. Despite major advances in the medical and device-related therapy including chronic resynchronization therapy for management of heart failure, significant number of patients eventually require advanced cardiac therapy including mechanical circulatory support or heart transplant. Heart transplant is a gold standard for end-stage heart failure but is limited by the donor heart shortage creating a definite need for alternative effective therapies. The earliest and most common form of mechanical circulatory support is counterpulsation therapy. Annually, more than 150,000 patients worldwide receive counterpulsation therapy for various indications including cardiogenic shock or severe left ventricular dysfunction (Nanas and Moulopoulos in Cardiology, 84:156–167, 1994) and many thousands of lives are saved each year (65 % survival) (Torchiana et al. in Journal of Thoracic and Cardiovascular Surgery, 113(4):758–764, 1997). There are different types of aortic counterpulsation devices. Here, we will give an overview of different counterpulsation devices with focus on C-Pulse device. Extra-aortic balloon counterpulsation, C-Pulse (Sunshine Heart Inc., Eden Prairie, MN), is an important and novel approach in the management of patients with advanced heart failure who remain symptomatic despite optimum medical and device-based therapy. C-Pulse is designed to provide permanent, long-term, continuous partial circulatory support for New York Heart Association class III and ambulatory class IV heart failure patients. C-Pulse is a nonblood-contacting counterpulsation using an inflatable cuff around the ascending aorta, extra-aortic balloon (EAB) counterpulsation device. A pivotal, multicenter US study to assess the safety and efficacy of C- Pulse in patient with Stage C and NYHA Class III or ambulatory Class IV heart failure is in progress.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Nanas, J. N., & Moulopoulos, S. D. (1994). Counterpulsation: historical background, technical improvements, hemodynamic and metabolic effects. Cardiology, 84, 156–167.

    Article  CAS  PubMed  Google Scholar 

  2. Torchiana, D. F., Hirsh, G., Buckley, M. J., et al. (1997). Intraaortic balloon pumping for cardiac support: trends in practice and outcome, 1968 to 1995. Journal of Thoracic and Cardiovascular Surgery, 113(4), 758–764.

    Article  CAS  PubMed  Google Scholar 

  3. Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., et al. (2005). ACC/AHA 2005 guideline update for the diagnosis and management of chronic heart failure in the adult: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing committee to update the 2001 guidelines for the evaluation and management of heart failure): developed in collaboration with the American College of Chest Physicians and the International Society for Heart and Lung Transplantation: endorsed by the Heart Rhythm Society. Circulation, 112, e154–e235.

    Article  PubMed  Google Scholar 

  4. Lloyd-Jones, D., Adams, R. J., Brown, T. M., Carnethon, M., Dai, S., De Simone, G., et al. (2010). Executive summary: heart disease and stroke statistics—2010 update: a report from the American Heart Association. Circulation, 121, 948–954.

    Article  PubMed  Google Scholar 

  5. Roger, V. L., Go, A. S., Lloyd-Jones, D. M., Adams, R. J., Berry, J. D., Brown, T. M., et al. (2011). Heart disease and stroke statistics—2011 update: a report from the American Heart Association. Circulation, 123, e18–e209.

    Article  PubMed  Google Scholar 

  6. Roger, V. L., Go, A. S., Lloyd-Jones, D. M., Benjamin, E. J., Berry, J. D., Borden, W. B., et al. (2012). Heart disease and stroke statistics—2012 update: a report from the American Heart Association. Circulation, 125, e2–e220.

    Article  PubMed  Google Scholar 

  7. The Captopril-Digoxin Multicenter Research Group. (1988). Comparative effects of therapy with captopril and digoxin in patients with mild to moderate heart failure. JAMA, 259, 539–544.

    Article  Google Scholar 

  8. Packer, M., Bristow, M. R., Cohn, J. N., et al. (1996). The effect of carvedilol on morbidity and mortality in patients with chronic heart failure. New England Journal of Medicine, 334, 1349–1355.

    Article  CAS  PubMed  Google Scholar 

  9. The RALES Investigators. (1996). Effectiveness of spironolactone added to an angiotensin-converting enzyme inhibitor and a loop diuretic for severe chronic congestive heart failure. American Journal of Cardiology, 78, 902–907.

    Article  Google Scholar 

  10. The SOLVD Investigators. (1991). Effect of enalapril on survival in patients with reduced left ventricular ejection fractions and congestive heart failure. New England Journal of Medicine, 325, 293–302.

    Article  Google Scholar 

  11. Kantrowitz, A. (1987). A moment in history: introduction of left ventricular assistance. ASAIO Journal, 10, 39.

    Google Scholar 

  12. Kantrowitz, A. (1953). Experimental augmentation of coronary flow by retardation of the arterial pressure pulse. Surgery, 34, 678–687.

    CAS  PubMed  Google Scholar 

  13. Kantrowitz, A. (1959). The experimental use of diaphragm as an auxiliary ventricle. Surgical Forum, 9, 266.

    Google Scholar 

  14. Cochran, R. P., Starkey, T. D., Panos, A. L., et al. (2002). Ambulatory intraaortic balloon pump use as bridge to heart transplant. Annals of Thoracic Surgery, 74, 746–752.

    Article  PubMed  Google Scholar 

  15. Kantrowitz, A., Krakauer, J., Rubenfire, M., et al. (1972). Initial clinical experience with a new permanent mechanical auxiliary ventricle: the dynamic aortic patch. Transactions of the American Society for Artificial Internal Organs, 18, 159–167.

    Article  CAS  PubMed  Google Scholar 

  16. Trainini, J., Cabrera Fischer, E. I., Barisani, J., et al. (2002). Dynamic aortomyoplasty in treating end-stage heart failure. Journal of Heart and Lung Transplantation, 21, 1068–1073.

    Article  PubMed  Google Scholar 

  17. Cheung, A. T. S. J., & Weiss, S. J. (1996). Beat-to-beat augmentation of left ventricular function by intraaortic counterpulsation. Anesthesiology, 84, 545–554.

    Article  CAS  PubMed  Google Scholar 

  18. Cochran, R. P., Starkey, T. D., Panos, A. L., & Kunzelman, K. S. (2002). Ambulatory intraaortic balloon pump use as bridge to heart transplant. Annals of Thoracic Surgery, 74, 746–751. discussion 751-742.

    Article  PubMed  Google Scholar 

  19. Scheidt, S. W. G., Mueller, H., et al. (1973). Intra-aortic balloon counterpulsation in cardiogenic shock. New England Journal of Medicine, 288, 979–984.

    Article  CAS  PubMed  Google Scholar 

  20. Lefemine, A. A., Low, H. B., Cohen, M. L., Lunzer, S., & Harken, D. E. (1962). Assisted circulation. III. The effect of synchronized arterial counterpulsation on myocardial oxygen consumption and coronary flow. American Heart Journal, 64, 789–795.

    Article  CAS  PubMed  Google Scholar 

  21. Kern, M. J., Aguirre, F. V., Tatineni, S., Penick, D., Serota, H., Donohue, T., et al. (1993). Enhanced coronary blood flow velocity during intraaortic balloon counterpulsation in critically ill patients. Journal of the American College of Cardiology, 21, 359–368.

    Article  CAS  PubMed  Google Scholar 

  22. Ishihara, M., Sato, H., Tateishi, H., Kawagoe, T., Muraoka, Y., & Yoshimura, M. (1992). Effects of intraaortic balloon pumping on coronary hemodynamics after coronary angioplasty in patients with acute myocardial infarction. American Heart Journal, 124, 1133–1138.

    Article  CAS  PubMed  Google Scholar 

  23. Papaioannou, T. G., & Stefanadis, C. (2005). Basic principles of the intraaortic balloon pump and mechanisms affecting its performance. ASAIO Journal, 51, 296–300.

    Article  PubMed  Google Scholar 

  24. Dunkman, W. B., Leinbach, R. C., Buckley, M. J., Mundth, E. D., Kantrowitz, A. R., Austen, W. G., et al. (1972). Clinical and hemodynamic results of intraaortic balloon pumping and surgery for cardiogenic shock. Circulation, 46, 465–477.

    Article  CAS  PubMed  Google Scholar 

  25. Bhayana, J. N., Scott, S. M., Sethi, G. K., & Takaro, T. (1979). Effects of intraaortic balloon pumping on organ perfusion in cardiogenic shock. Journal of Surgical Research, 26, 108–113.

    Article  CAS  PubMed  Google Scholar 

  26. Sugita, Y., Emoto, H., Morita, K., Suzuki, K., & Arai, T. (1985). The effect of intraaortic balloon pumping (IABP) on pulmonary circulation. Transactions of the American Society for Artificial Internal Organs, 31, 389–394.

    CAS  PubMed  Google Scholar 

  27. Hilberman, M., Derby, G. C., Spencer, R. J., & Stinson, E. B. (1981). Effect of the intra-aortic balloon pump upon postoperative renal function in man. Critical Care Medicine, 9, 85–89.

    Article  CAS  PubMed  Google Scholar 

  28. Lawson, W. E., Hui, J. C., Zheng, Z. S., et al. (1996). Improved exercise tolerance following enhanced external counterpulsation: cardiac or peripheral effect? Cardiology, 87(4), 271–275.

    Article  CAS  PubMed  Google Scholar 

  29. Arora, R. R., Chou, T. M., Jain, D., et al. (1999). The multicenter study of enhanced external counterpulsation (MUST-EECP): effect of EECP on exercise-induced myocardial ischemia and anginal episodes. Journal of the American College of Cardiology, 33(7), 1833–1840.

    Article  CAS  PubMed  Google Scholar 

  30. Werner, D., Schneider, M., Weise, M., Nonnast-Daniel, B., & Daniel, W. G. (1999). Pneumatic external counterpulsation: a new noninvasive method to improve organ perfusion. American Journal of Cardiology, 84(8), 950–952. A957-958.

    Article  CAS  PubMed  Google Scholar 

  31. Feldman, A. M., Silver, M. A., Francis, G. S., De Lame, P. A., & Parmley, W. W. (2005). Treating heart failure with enhanced external counterpulsation (EECP): design of the Prospective Evaluation of EECP in Heart Failure (PEECH) trial. Journal of Cardiac Failure, 11(3), 240–245.

    Article  PubMed  Google Scholar 

  32. Schreuder, J. J., Maisano, F., Donelli, A., et al. (2005). Beat-to-beat effects of intraaortic balloon pump timing on left ventricular performance in patients with low ejection fraction. Annals of Thoracic Surgery, 79(3), 872–880.

    Article  PubMed  Google Scholar 

  33. Meyns, B. P., Nishimura, Y., Jashari, R., Racz, R., Leunens, V. H., & Flameng, W. J. (2000). Ascending versus descending aortic balloon pumping: organ and myocardial perfusion during ischemia. Annals of Thoracic Surgery, 70, 1264–1269.

    Article  CAS  PubMed  Google Scholar 

  34. Freed, P. S., Wasfie, T., Zado, B., & Kantrowitz, A. (1988). Intraaortic balloon pumping for prolonged circulatory support. American Journal of Cardiology, 61, 554–557.

    Article  CAS  PubMed  Google Scholar 

  35. Legget, M. E., Peters, W. S., Milson, F. P., Clark, J. S., West, T. M., French, R. L., et al. (2005). Extra-aortic balloon counterpulsation. Circulation, 112(9 Suppl), I26–I31.

    PubMed  Google Scholar 

  36. Jeevanandam, V., Jayakar, D., Anderson, A. S., et al. (2002). Circulatory assistance with a permanent implantable IABP: initial human experience. Circulation, 106(12 Suppl. 1), I-183–I-188.

    Google Scholar 

  37. Koenig, S. C., Spence, P. A., Pantalos, G. M., Dowling, R. D., & Litwak, K. N. (2006). Development and early testing of a simple subcutaneous counterpulsation device. ASAIO Journal, 52(4), 362–367.

    Article  PubMed Central  PubMed  Google Scholar 

  38. Giridharan, G. A., Pantalos, G. M., Litwak, K. N., Spence, P. A., & Koenig, S. C. (2006). Predicted hemodynamic benefits of counterpulsation therapy using a superficial surgical approach. ASAIO Journal, 52(1), 39–46.

    Article  PubMed Central  PubMed  Google Scholar 

  39. Sales, V. L., & McCarthy, P. M. (2010). Understanding the c-pulse device and its potential to treat heart failure. Current Heart Failure Reports, 7, 27–34.

    Article  PubMed  Google Scholar 

  40. Hayward, C. S., Peters, W. S., Merry, A. F., et al. (2010). Chronic extra-aortic balloon counterpulsation: first-in-human pilot study in endstage heart failure. Journal of Heart and Lung Transplantation, 29, 1427–1432.

    Article  PubMed  Google Scholar 

  41. Davies, A. N., Peters, W. S., Su, T., Sullivan, C. E., Perkidides, T., Milsom, F. P., et al. (2005). Extra-ascending aortic versus intra-descending aortic balloon counterpulsation-effect on coronary artery blood flow. Heart, Lung & Circulation, 14(3), 178–186.

    Article  Google Scholar 

  42. Furman, S., Whitman, R., Stewart, J., Parker, B., & McMullen, M. (1971). Proximity to aortic valve and unidirectionality as prime factors in counterpulsation effectiveness. Transactions of the American Society for Artificial Internal Organs, 17, 153–159.

    CAS  PubMed  Google Scholar 

Download references

Conflict of Interest

I am an advanced heart failure cardiologist and manage patients with different types of mechanical circulatory support devices.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Pallavi Solanki.

Additional information

Associate Editor Craig Stolen oversaw the review of this article

Rights and permissions

Reprints and permissions

About this article

Cite this article

Solanki, P. Aortic Counterpulsation: C-Pulse and Other Devices for Cardiac Support. J. of Cardiovasc. Trans. Res. 7, 292–300 (2014). https://doi.org/10.1007/s12265-014-9548-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12265-014-9548-6

Keywords

Navigation