Abstract
The aim of the study was to evaluate the perturbation correction factors at a reference depth for cylindrical ionization chambers in high-energy electron beams by means of the EGSnrc Monte Carlo user code cavity. The cylindrical chambers used in this study were the Farmer-type of PTW30010, PTW30011, PTW30012, and PTW30013 models. We calculated the wall correction factor, P wall, the cavity or electron fluence correction factor, P cav, the stem correction factor, P stem, the central electrode correction factor, P cel, and the overall perturbation correction factor, P Q, for each chamber. The calculated P cav values were higher by from 2 to 1% than those recommended by the IAEA-TRS-398 code of practice, in an energy range of 6–18 MeV. The P wall values almost agreed with the analytical calculation performed with IAEA-TRS-398. The P cel values agreed with those of Ma and Nahum, performed with IAEA-TRS-398. The P stem values were approximately 0.995 on average and were independent of the electron beam energy. P stem needs to be considered in future dosimetry protocols. The P Q values were higher from 1 to 2% than those of IAEA-TRS-398 in an energy range of 6–18 MeV.
Similar content being viewed by others
References
IAEA. Absorbed dose determination in external beam radiotherapy, Technical Report Series 398. IAEA, Vienna; 2000.
Johasson KA, Mattoson LO, Lindborg L, Svensson H. Absorbed dose determination with ionization chambers in electron and photon beams having energies between 1 and 50 MeV, National and International Standardization of Radiation Dosimetry. IAEA, Vienna. 1978;2:20–243.
Ma CM, Nahum AE. Effect of size and composition of the central electrode on the response of cylindrical ionization chambers in high-energy photon and electron beams. Phys Med Biol. 1993;38:267–90.
Buckley LA, Rogers DWO. Wall correction factors, P wall, for thimble ionization chambers. Med Phys. 2006;33:455–64.
Buckley LA, Kawrakow I, Rogers DWO. CSnrc: correlated sampling Monte Carlo calculations using EGSnrc. Med Phys. 2004;31:3425–35.
Wang LLW, Rogers DWO. Study of the effective point of measurement for ion chambers in electron beams by Monte Carlo simulation. Med Phys. 2009;36:2034–42.
Wang LLW, Rogers DWO. Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation. Med Phys. 2008;35:1747–55.
Kawrakow I, Rogers DWO. The EGSnrc code system: Monte Carlo simulation of electron and photon transport. National Research Council of Canada Report PIRS-701; 2009.
Kawrakow I. egspp: the EGSnrc C++ class library. National Research Council of Canada Report PIRS-899; 2005.
Rogers DWO, Faddegon BA, Ding GX, Ma CM, We J, Mackie TR. BEAM: a Monte Carlo code to simulate radiotherapy treatment units. Med Phys. 1995;22:503–24.
Rogers DWO, Walters B, Kawrakow I. BEAMnrc Users Manual. National Research Council of Canada Report PIRS-0509(A); 2009, Rev K.
Wullff J, Heverhagen JT, Zink K. Monte-Carlo-based perturbation and beam quality correction factors for thimble ionization chambers in high-energy photon beams. Phys Med Biol. 2008;53:2823–36.
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Ono, T., Araki, F. & Yoshiyama, F. Perturbation correction factors for cylindrical ionization chambers in high-energy electron beams. Radiol Phys Technol 3, 93–97 (2010). https://doi.org/10.1007/s12194-010-0082-1
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12194-010-0082-1