Abstract
Background Vancomycin therapeutic drug monitoring (TDM) is commonly performed to ensure safe and effective use of the antibiotic. Aim of Study To evaluate appropriateness of vancomycin TDM and its outcomes in Singapore General Hospital. Method A retrospective, cross-sectional study was conducted between 1 January 2014 and 28 February 2014 involving patients who received ≥ 1 dose of intravenous vancomycin with TDM. Patient demographics and relevant vancomycin TDM data were collected from medical records. Results Of 746 vancomycin troughs measured among 234 patients, 459 troughs (61.5%) were taken inappropriately, with a median time of 2.6 h (interquartile range 1.1–4.3) before the next scheduled dose. Inappropriate interpretation of vancomycin troughs resulted in 41 unnecessary dose suspensions, 24 dose changes, and 102 unchanged vancomycin doses. The cost incurred due to inappropriate interpretation and measurement after discontinuation of treatment was US$7286. No differences in rates of vancomycin related nephrotoxicity, ototoxicity, recurrent infection, development of infection secondary to vancomycin resistant microorganism and mortality were observed (p > 0.05). Conclusion This study highlighted a high incidence of inappropriate vancomycin TDM which has led to increased healthcare cost.
References
Moise-Broder PA, Forrest A, Birmingham MC, Schentag JJ. Pharmacodynamics of vancomycin and other antimicrobials in patients with Staphylococcus aureus lower respiratory tract infections. Clin Pharmacokinet. 2004;43(13):925–42.
Giuliano C, Haase KK, Hall R. Use of vancomycin pharmacokinetic-pharmacodynamic properties in the treatment of MRSA infections. Expert Rev Anti-Infect Therapy. 2010;8(1):95–106.
Rybak M, Lomaestro B, Rotschafer JC, Moellering R Jr, Craig W, Billeter M, et al. Therapeutic monitoring of vancomycin in adult patients: a consensus review of the American Society of Health-System Pharmacists, the Infectious Diseases Society of America, and the Society of Infectious Diseases Pharmacists. Am J Health Syst Pharm. 2009;66(1):82–98.
Bates DW. Improving the use of therapeutic drug monitoring. Ther Drug Monit. 1998;20(5):550–5.
Traugott KA, Maxwell PR, Green K, Frei C, Lewis JS 2nd. Effects of therapeutic drug monitoring criteria in a computerized prescriber-order-entry system on the appropriateness of vancomycin level orders. Am J Health Syst Pharm. 2011;68(4):347–52.
Swartling M, Gupta R, Dudas V, Guglielmo BJ. Short term impact of guidelines on vancomycin dosing and therapeutic drug monitoring. Int J Clin Pharm. 2012;34(2):282–5.
Suryadevara M, Steidl KE, Probst LA, Shaw J. Inappropriate vancomycin therapeutic drug monitoring in hospitalized pediatric patients increases pediatric trauma and hospital costs. J Pediatr Pharmacol Ther. 2012;17(2):159–65.
Matzke GR, McGory RW, Halstenson CE, Keane WF. Pharmacokinetics of vancomycin in patients with various degrees of renal function. Antimicrob Agents Chemother. 1984;25(4):433–7.
Carroll DJ, Austin GE, Stajich GV, Miyahara RK, Murphy JE, Ward ES. Effect of education on the appropriateness of serum drug concentration determination. Ther Drug Monit. 1992;14(1):81–4.
Pea F, Porreca L, Baraldo M, Furlanut M. High vancomycin dosage regimens required by intensive care unit patients cotreated with drugs to improve haemodynamics following cardiac surgical procedures. J Antimicrob Chemother. 2000;45(3):329–35.
Acknowledgements
We would like to thank Ms. Ang Xiao Hui for assisting with the data collection.
Funding
None.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflicts of interest
The authors declare that they have no conflicts of interest.
Rights and permissions
About this article
Cite this article
Seng, J.J.B., Yong, M.H.A., Peh, Z.X. et al. Appropriateness of vancomycin therapeutic drug monitoring and its outcomes among non-dialysis patients in a tertiary hospital in Singapore. Int J Clin Pharm 40, 977–981 (2018). https://doi.org/10.1007/s11096-018-0670-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11096-018-0670-4