The Impact of Voxel Size-Based Inaccuracies on the Mechanical Behavior of Thin Bone Structures

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

Computed tomography (CT)-based measures of skeletal geometry and material properties have been widely used to develop finite element (FE) models of bony structures. However, in the case of thin bone structures, the ability to develop FE models with accurate geometry derived from clinical CT data presents a challenge due to the thinness of the bone and the limited resolution of the imaging devices. The purpose of this study was to quantify the impact of voxel size on the thickness and intensity values of thin bone structure measurements and to assess the effect of voxel size on strains through FE modeling. Cortical bone thickness and material properties in five thin bone specimens were quantified at voxel sizes ranging from 16.4 to 488 μm. The measurements derived from large voxel size scans showed large increases in cortical thickness (61.9–252.2%) and large decreases in scan intensity (12.9–49.5%). Maximum principal strains from FE models generated using scans at 488 μm were decreased as compared to strains generated at 16.4 μm voxel size (8.6–64.2%). A higher level of significance was found in comparing intensity (p = 0.0001) vs. thickness (p = 0.005) to strain measurements. These findings have implications in developing methods to generate accurate FE models to predict the biomechanical behavior of thin bone structures.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8

Similar content being viewed by others

References

  1. Anderson, A. E., C. L. Peters, B. D. Tuttle, and J. A. Weiss. Subject-specific finite element model of the pelvis: development, validation and sensitivity studies. J. Biomech. Eng. 127:364–373, 2005.

    Article  PubMed  Google Scholar 

  2. Chen, G., B. Schmutz, D. Epari, K. Rathnayaka, S. Ibrahim, M. A. Schuetz, and M. J. Pearcy. A new approach for assigning bone material properties from CT images into finite element models. J. Biomech. 43:1011–1015, 2010.

    Article  CAS  PubMed  Google Scholar 

  3. Hangartner, T. N. Thresholding technique for accurate analysis of density and geometry in QCT, pQCT and microCT images. J. Musculoskelet. Neuronal Interact. 7:9–16, 2007.

    CAS  PubMed  Google Scholar 

  4. Hangartner, T. N., and V. Gilsanz. Evaluation of cortical bone by computed tomography. J. Bone Miner. Res. 11:1518–1525, 1996.

    Article  CAS  PubMed  Google Scholar 

  5. Hangartner, T. N., and T. R. Overton. Quantitative measurement of bone density using gamma-ray computed tomography. J. Comput. Assist. Tomogr. 6:1156–1162, 1982.

    Article  CAS  PubMed  Google Scholar 

  6. Helgason, B., F. Taddei, H. Palsson, E. Schileo, L. Cristofolini, M. Viceconti, and S. Brynjolfsson. A modified method for assigning material properties to FE models of bones. Med. Eng. Phys. 30:444–453, 2008.

    Article  PubMed  Google Scholar 

  7. Hounsfield, G. N. Computerized transverse axial scanning (tomography). Part I. Description of system. Br. J. Radiol. 68:H166–H172, 1995.

    CAS  PubMed  Google Scholar 

  8. Huiskes, R., and S. J. Hollister. From structure to process, from organ to cell: recent developments of FE-analysis in orthopaedic biomechanics. J. Biomech. Eng. 115:520–527, 1993.

    Article  CAS  PubMed  Google Scholar 

  9. Kim, C. H., H. Zhang, G. Mikhail, D. von Stechow, R. Muller, H. S. Kim, and X. E. Guo. Effects of thresholding techniques on microCT-based finite element models of trabecular bone. J. Biomech. Eng. 129:481–486, 2007.

    Article  PubMed  Google Scholar 

  10. Mora, S., W. G. Goodman, M. L. Loro, T. F. Roe, J. Sayre, and V. Gilsanz. Age-related changes in cortical and cancellous vertebral bone density in girls: assessment with quantitative CT. AJR Am. J. Roentgenol. 162:405–409, 1994.

    CAS  PubMed  Google Scholar 

  11. Newman, D. L., G. Dougherty, A. Al Obaid, and H. Al Hajrasy. Limitations of clinical CT in assessing cortical thickness and density. Phys. Med. Biol. 43:619–626, 1998.

    Article  CAS  PubMed  Google Scholar 

  12. Newton, T. H., and D. G. Potts. Radiology of the skull and brain. In: Anatomy and Pathology, edited by T. H. Newton, and D. Gordon Potts. Saint Louis: Mosby, 1971.

    Google Scholar 

  13. Prevrhal, S., K. Engelke, and W. A. Kalender. Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters. Phys. Med. Biol. 44:751–764, 1999.

    Article  CAS  PubMed  Google Scholar 

  14. Silva, M. J., C. Wang, T. M. Keaveny, and W. C. Hayes. Direct and computed tomography thickness measurements of the human, lumbar vertebral shell and endplate. Bone 15:409–414, 1994.

    Article  CAS  PubMed  Google Scholar 

  15. Szwedowski, T. D., F. Fialkov, and C. M. Whyne. Sensitivity analysis of a validated subject-specific finite element model of the human craniofacial skeleton. Proc. Inst. Mech. Eng. H 224:1–10, 2010

    Google Scholar 

  16. Taddei, F., A. Pancanti, and M. Viceconti. An improved method for the automatic mapping of computed tomography numbers onto finite element models. Med. Eng. Phys. 26:61–69, 2004.

    Article  PubMed  Google Scholar 

  17. Treece, G. M., A. H. Gee, P. M. Mayhew, and K. E. Poole. High resolution cortical bone thickness measurement from clinical CT data. Med. Image Anal. 14:276–290, 2010.

    Article  CAS  PubMed  Google Scholar 

  18. Zannoni, C., R. Mantovani, and M. Viceconti. Material properties assignment to finite element models of bone structures: a new method. Med. Eng. Phys. 20:735–740, 1998.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgments

The authors would like to thank Dr. Alex Kiss for assisting in determining the appropriate statistical analyses for this study. They also would like to acknowledge the use of the High Performance Facility at the Centre for Computational Biology at the Hospital for Sick Children for the computational analyses. This work was financially supported by the Natural Sciences and Engineering Research Council of Canada and the Osteosynthesis and Trauma Care Foundation.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Cari Whyne.

Additional information

Associate Editor Sean S. Kohles oversaw the review of this article.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Maloul, A., Fialkov, J. & Whyne, C. The Impact of Voxel Size-Based Inaccuracies on the Mechanical Behavior of Thin Bone Structures. Ann Biomed Eng 39, 1092–1100 (2011). https://doi.org/10.1007/s10439-010-0215-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10439-010-0215-z

Keywords

Navigation