Skip to main content
Log in

A class-selective and reliable electrochemical monosaccharide index in honeys, as determined using nickel and nickel-copper nanowires

  • Original Paper
  • Published:
Analytical and Bioanalytical Chemistry Aims and scope Submit manuscript

Abstract

The electrochemical detection of sugars is favored by the electrocatalytic effects of copper and nickel, which allow their detection with high sensitivity and without the need for derivatization. Also, novel nanotechnological tools known as metallic nanowires (NWs) may offer new possibilities for sensing, since their large active surfaces allow greatly enhanced sensitivity. In this work, nickel (NiNWs) and nickel-copper (Ni-CuNWs 50:50 w/w) nanowires were synthesized by electroplating using an alumina template, and characterized by scanning electronic microscopy (SEM), transmission electronic microscopy (TEM), and energy-dispersive X-ray spectrometry (EDS). Using an alumina template of 200 nm, and under the controlled deposition of 45 C of charge, both of these NWs were obtained with lengths of about 7 μm and widths of about 300 μm. EDS analysis confirmed that the percentage of Ni in the NiNWs was 97%, and the percentages of Ni and Cu in the Ni-CuNWs were 50.6% and 49.4%, respectively. Both of the electrosynthesized NW exhibited enhanced electrocatalytic properties (and therefore improved detection sensitivity) toward the target sugars. Analytical performance was then evaluated by analyzing ten target honeys, utilizing a simplified calibration strategy that employed a glucose:fructose mixture as the standard. Repeatability was excellent when calibration (RSDs ≤ 5%) and sample analysis (RSDs ≤ 6%) protocols were performed. The total sugar content obtained by the electrochemical approach was compared with that obtained using a HPLC-RI (refractive index) method. The novel method gave low systematic errors, revealing that it afforded very accurate results. Also, a high throughput was achieved, as 60 samples were processed in about 25 min (yielding a rate of 2 samples min−1) on a board containing just one electrode, without any loss of performance. While both electrosynthesized NWs exhibited good analytical performance, the NiNWs were judged to be the most suitable for use in a sensor because of their easy preparation, stability, and magnetic properties. Nanowire-based disposable screen-printed detectors that are strategically connected to miniaturized instrumentation represent a novel approach that could be used in standard labs.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3a–b
Fig. 4a–c

Similar content being viewed by others

References

  1. Martínez Montero C, Rodríguez Dodero MC, Guillén Sánchez DA, Barroso CG (2004) Analysis of low carbohydrates in food and beverages: a review. Chromatographia 59:15–30

    Google Scholar 

  2. Herrero M, García-Cabañas V, Simo C, Cifuentes A (2010) Recent advances in the application of capillary electromigration methods for food analysis and Foodomics. Electrophoresis 31:205–228

    Article  CAS  Google Scholar 

  3. Harvey DJ (2011) Derivatization of carbohydrates for analysis by chromatography, electrophoresis and mass spectrometry. J Chromatogr B 879:1196–1225

    Google Scholar 

  4. Vidotti M, Cerri CD, Carvalhal RF, Dias JC, Mendes RK, Cordoba de Torresi SI, Kubota LT (2009) Nickel hidroxide electrodes as amperometric detectors for carbohydrates in flow injection analysis and liquid chromatography. J Electroanal Chem 636:18–23

    Article  CAS  Google Scholar 

  5. Wang J (2005) Electrochemical detection for capillary electrophoresis microchips: a review. Electroanalysis 7:1133–1140

    Article  Google Scholar 

  6. Menon VP, Martin CR (1995) Fabrication and evaluation of nanoelectrode ensembles. Anal Chem 67:1920–1928

    Article  CAS  Google Scholar 

  7. Ugo P, Moretto LM, Vezza F (2002) Ionomer-coated electrodes and nanoelectrode ensembles as electrochemical enviromental sensors: recent advances and prospects. Chem Phys Chem 3:917–925

    Article  CAS  Google Scholar 

  8. Hangarter CM, Myung NV (2005) Magnetic alignment of nanowires. Chem Mater 17:1320–1324

    Article  CAS  Google Scholar 

  9. Liu L, Song JF, Yu PF, Cui B (2006) A novel electrochemical sensing system for inosine and its application for inosine determination in pharmaceuticals and human serum. Electrochem Commun 8:1521–1526

    Article  Google Scholar 

  10. Tanase M, Bauer LA, Hultgren A, Silevitch DM, Sun L, Reich DH, Searson PC, Meyer GJ (2001) Magnetic alignment of fluorescent nanowires. Nano Lett 1:155–158

    Google Scholar 

  11. Wang J (2008) Adaptive nanowires for on-demand control of electrochemical microsystems. Electroanalysis 20:611–615

    Google Scholar 

  12. Piccin E, Laocharoensuk R, Burdick J, Carrillo E, Wang J (2007) Adaptive nanowires for switchable microchip devices. Anal Chem 79:4720–4723

    Article  CAS  Google Scholar 

  13. Wang J, Scampicchio M, Laocharoensuk R, Valentini F, González-García O, Burdick J (2006) Magnetic tuning of the electrochemical reactivity through controlled surface orientation of catalytic nanowires. J Am Chem Soc 128:4562–4563

    Article  CAS  Google Scholar 

  14. Tao B, Zhang J, Hui S, Wan L (2009) An amperometric ethanol sensor based on a Pd–Ni/SiNWs electrode. Sensor Actuat B 142:298–303

    Google Scholar 

  15. Tao B, Zhang J, Hui S, Chen X, Wan L (2010) An electrochemical methanol sensor based on a Pd–Ni/SiNWs catalytic electrode. Electrochim Acta 55:5019–5023

    Article  CAS  Google Scholar 

  16. Hoa ND, Quy NV, Jung H, Kim D, Kim H, Hong S (2010) Synthesis of porous CuO nanowires and its application to hydrogen detection. Sensor Actuat B 146:266–272

    Google Scholar 

  17. Garcia M, Escarpa A (2011) Disposable electrochemical detectors based on nickel nanowires for carbohydrate sensing. Biosens Bioelectron 26:2527–2533

    Article  CAS  Google Scholar 

  18. Metters JP, Kadara RO, Banks CE (2011) New directions in screen printed electroanalytical sensor: an overview of recent developments. Analyst 136:1067–1076

    Article  CAS  Google Scholar 

  19. Brainina KZ (2001) Electroanalysis: from laboratory to field versions. Anal Chem 56:303–312

    Article  CAS  Google Scholar 

  20. Hart JP, Wring SA (1997) Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses. Trends Anal Chem 16:89–103

    Google Scholar 

  21. Bulbarello A, Sattayasamitsathit S, Crevillen AG, Burdick J, Mannino S, Kanatharana P, Thavarungkul P, Escarpa A, Wang J (2008) Striped alloy nanowire optical reflectance barcodes prepared from a single plating solution. Small 4:597–600

    Article  CAS  Google Scholar 

  22. Wang J, Chen G, Chatrathi MP (2004) Nickel amperometric detector prepared by electroless deposition for microchip electrophoretic measurement of alcohols and sugars. Electroanalysis 16:1603–1608

    Article  CAS  Google Scholar 

  23. Zhao C, Shao C, Li M, Jiao K (2007) Flow-injection analysis of glucose without enzyme based on electrocatalytic oxidation of glucose at a nickel electrode. Talanta 71:1769–1773

    Article  CAS  Google Scholar 

  24. Perez RA, Iglesias MT, Puedo E, González M, De Lorenzo C (2007) Amino Acid composition and antioxidant capacity of Spanish honeys. J Agric Food Chem 55:360–365

    Article  CAS  Google Scholar 

  25. Ávila M, Crevillén AG, González MC, Escarpa A, Hortigüela LV, Carretero CL, Pérez-Martín RA (2006) Electroanalytical approach to evaluate antioxidant capacity in honeys: proposal of antioxidant index. Electroanalysis 18:1821–1826

    Article  Google Scholar 

Download references

Acknowledgements

Financial support from the Spanish Ministry of Science and Innovation (CTQ2008-06730-CO2-02/BQU) and the AVANSENS program from the Community of Madrid (P2009/PPQ-1642) is gratefully acknowledged. M. García acknowledges the fellowship received from Alcalá University. The authors also thank Dr. Rosa Ana Pérez for her valuable help during the characterization and analysis of the honeys by HPLC-RI.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alberto Escarpa.

Rights and permissions

Reprints and permissions

About this article

Cite this article

García, M., Escarpa, A. A class-selective and reliable electrochemical monosaccharide index in honeys, as determined using nickel and nickel-copper nanowires. Anal Bioanal Chem 402, 945–953 (2012). https://doi.org/10.1007/s00216-011-5453-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00216-011-5453-x

Keywords

Navigation