Abstract
Purpose/objective Long-term complications from anti-incontinence surgical procedures are rarely reported. We report on delayed presentation of complications relating to the synthetic bolster placed for the Stamey bladder neck suspension. Materials and methods: Patients undergoing re-operative surgery following prior Stamey endoscopic bladder neck suspension were selected from a surgical database. Four women with lower urinary tract and/or vaginal symptoms following prior Stamey endoscopic bladder neck suspension were identified. All patients had undergone removal of the bolster material by a single surgeon (ESR) at re-operation. Preoperative, operative, and postoperative inpatient and outpatient records were reviewed. Results: Patients presented with a variety of symptoms including urinary incontinence, recurrent cystitis, vaginitis, and urinary frequency at 9, 11, 11, and 12 years after Stamey bladder neck suspension. In addition, two patients presented with recurrent, intermittent bloody vaginal discharge and two patients complained of recurrent urinary tract infections and irritative voiding symptoms. All patients underwent transvaginal excision of the Dacron bolster. Three patients also underwent placement of an autologous pubovaginal sling for symptomatic recurrent stress urinary incontinence. At a mean follow-up of 30 months all four patients were improved. There was no recurrence of vaginal discharge or urinary tract infections. Irritative voiding symptoms resolved. Conclusions: Delayed complications from surgically implanted synthetic materials can present many years after initial implantation. The clinical findings are often subtle and require a high degree of suspicion. Vaginal discharge and irritative urinary symptoms in patients with even a remote history of Stamey bladder neck suspension should prompt a thorough vaginal exam and cystoscopy. Excision of the bolsters can be performed and is usually followed by symptomatic improvement.
Similar content being viewed by others
References
Leach GE, Dmochowski RR, Appell RA, Blaivis JG, Hadley HR, Luber KM, Mostwin JL, O’Donnell PD, Roehrborn CG (1997) Female stress incontinence clinical guidelines panel summary report on surgical management of female stress urinary incontinence. J Urol 158:875–880
Stamey TA (1973) Endoscopic suspension of the vesical neck for urinary incontinence. Surg Gynecol Obstet 136:547–554
Stamey TA (1980) Endoscopic suspension of the vesical neck for urinary incontinence in females: A report of 203 consecutive patients. Ann Surg 192:465–471
Huland H, Bucher H (1984) Endoscopic bladder neck suspension (Stamey–Pereyra) in female urinary stress incontinence. Long-term follow-up of 66 patients. Eur Urol 10:238–241
Spencer JR, O’Connor VJ Jr, Schaeffer AJ (1987) A comparison of endoscopic suspension of the vesical neck with suprapubic vesicourethropexy for treatment of stress urinary incontinence. J Urol 137(3):411–415
Fowler JE (1986) Experience with suprapubic vesicourethral suspension and endoscopic suspension of the vesical neck for stress urinary incontinence in females. Surg Gynecol Obstet 162(5):437–441
Hilton P (1989) A clinical and urodynamic study comparing the Stamey bladder neck suspension and suburethral sling procedures in the treatment of gennuine stress incontinence. Br J Obstet Gynaecol 96(2):213–220
Loughlin KR, Whimore WF III, Gittes RF, Richie JP (1990) Review of an 8-year experience with modifications of the endoscopic suspension of the bladder neck for female stress urinary incontinence. J Urol 143(1):44–45
Takahashi S, Miyao N, Hisataki T, Matsukawa M, Takagi S, Sasao T, Adachi H, Miyake M, Tsukamoto T (2002) Complications of Stamey needle suspension for female stress urinary incontinence. Urol Int 68:148–151
Athanasopoulos A, Liatsikos EN, Perimenis P, Barbalias GA (2002) Delayed suture intravesical migration as a complication of a Stamey endoscopic bladder neck suspension. Int Urol Nephrol 34(1):5–7
Biyani CS, Upsdell SM (1998) An unusual foreign body in the bladder 7 years after a Stamey endoscopic bladder neck suspension. Int Urogynecol J Pelvic Floor Dysfunct 9(5):303–304
Nabi G, Hemal AK, Khaitan A (2001) Endoscopic management of an unusual foreign body in the urinary bladder leading to intractable symptoms. Int Urol Nephrol 33(2):351–352
Richardson DA, Bent AE, Ostergard DR, Cannon D (1984) Delayed reaction to the Dacron buttress used in urethropexy. J Reprod Med 29(9):689–692
Clemens JQ, Stern JA, Bushman WA, Schaeffer AJ (1998) Long-term results of the Stamey bladder neck suspension: direct comparison with the Marshall–Marchetti–Krantz procedure. J Urol 160:372–376
Spencer JR, O’Conor VJ, Schaeffer AJ (1987) A comparison of endoscopic suspension of the vesical neck with suprapubic vesicourethropexy for treatment of stress urinary incontinence. J Urol 137:411–415
Bihrle W 3rd, Tarantino AF (1990) Complication of retropubic bladder neck suspension. Urology 35(3):213–214
Conrad S, Peiper A, De la Maza SF, Busch R, Huland H (1997) Long term results of the Stamey bladder neck suspension procedure: a patient questionnaire based outcome analysis. J Urol 157(5):1672–1677
Kirby RS, Whiteway JE (1989) Assessment of the results of Stamey bladder neck suspension. Br J Urol 63(1):21–23
Stanford EJ, Levy B, Rosenblatt PL (2005) The use of mesh in pelvic reconstructive surgery. Suppl OBG Manage, pp 81–99
Bafghi A, Benizri EI, Trastour C, Benizri EJ, Michiels JF, Bongain A (2005) Multifilament polypropylene mesh for urinary incontinence: 10 cases of infections requiring removal of the sling. BJOG 112:376–378
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Smith, A., Rovner, E. Long-term chronic complications from Stamey endoscopic bladder neck suspension: a case series. Int Urogynecol J 17, 290–294 (2006). https://doi.org/10.1007/s00192-005-1332-3