The effect of extraction, storage, and analysis techniques on the measurement of airborne endotoxin from a large dairy

  • Original Paper
  • Published:
Aerobiologia Aims and scope Submit manuscript

Abstract

The objective of this study was to fill in additional knowledge gaps with respect to the extraction, storage, and analysis of airborne endotoxin, with a specific focus on samples from a dairy production facility. We utilized polycarbonate filters to collect total airborne endotoxins, sonication as the extraction technique, and 0.05% Tween 20 in pyrogen-free water (PFW) as the extraction solution. Endotoxin concentrations were determined via the Limulus amebocyte lysate (LAL) assay. The endotoxin concentrations in extracts after 15 and 30 min of filter sonication were similar, while the concentration in 60 min extracts was about twofold lower. Rapidly vortexing samples for up to 15 min after sonication did not increase the endotoxin concentration. However, concentrations were 13 and 26% lower in extracts that were centrifuged at 1,000 and 10,000g for up to 15 min, respectively. Field samples and endotoxin standard were also sonicated in glass or polypropylene tubes for up to 120 min. Regardless of the extraction vessel, a decrease in endotoxin concentration occurred when sonicated for >30 min. Samples and endotoxin standard subjected to 12 freeze–thaw cycles at −20°C only showed a slight but not significant decrease in endotoxin concentration. Our results also demonstrate the importance of simultaneously adding LAL reagent to 96-well plates before initiating the LAL assay.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  • Bradley, S. G. (1979). Cellular and molecular mechanisms of action of bacterial endotoxins. Annual review of microbiology, 33, 67–94.

    Article  CAS  Google Scholar 

  • Castellan, R. M., Olenchock, S. A., Kinsley, K. B., & Hankinson, J. L. (1987). Inhaled endotoxin and decreased spirometric values. The New England journal of medicine, 317, 605–610.

    Article  CAS  Google Scholar 

  • Chang, C. W., Chung, H., Huang, C. F., & Su, H. J. J. (2001). Exposure of workers to airborne microorganisms in open-air swine houses. Applied and Environmental Microbiology, 67, 155–161.

    Article  CAS  Google Scholar 

  • Clark, C. S., Rylander, R., & Larsson, L. (1983). Levels of gram-negative bacteria, Aspergillus fumigatus, dust, and endotoxin at compost plants. Applied and Environmental Microbiology, 45, 1501–1505.

    CAS  Google Scholar 

  • Douwes, J., Versloot, P., Hollander, A., Heederik, D., & Doekes, G. (1995). Influence of various dust sampling and extraction methods on the measurement of airborne endotoxin. Applied and Environmental Microbiology, 61, 1763–1769.

    CAS  Google Scholar 

  • Duchaine, C., Thorne, P. S., Meriaux, A., Grimard, Y., Whitten, P., & Cormier, Y. (2001). Comparison of endotoxin exposure assessment by bioaerosol impinger and filter-sampling methods. Applied and Environmental Microbiology, 67, 2775–2780.

    Article  CAS  Google Scholar 

  • Dutkiewicz, J., Olenchock, S. A., Sorenson, W. G., Gerencser, V. F., May, J. J., Pratt, D. S., et al. (1989). Levels of bacteria, fungi, and endotoxin in bulk and aerosolized corn silage. Applied and Environmental Microbiology, 55, 1093–1099.

    CAS  Google Scholar 

  • Eduard, W., Douwes, J., Omenass, E., & Heederik, D. (2004). Do farming exposures cause or prevent asthma? Results from a study of adult Norwegian farmers. Thorax, 59, 381–386.

    Article  CAS  Google Scholar 

  • Holla, A. D., Roy, S. R., & Liu, A. H. (2002). Endotoxin, atopy and asthma. Current opinion in Allergy and Clinical Immunology, 2, 141–145.

    Article  Google Scholar 

  • Hollander, A., Heederik, D., Versloot, P., & Douwes, J. (1993). Inhibition and enhancement in the analysis of airborne endotoxin levels in various occupational environments. American Industrial Hygiene Association Journal, 54, 647–653.

    CAS  Google Scholar 

  • Jacobs, R. R. (1989). Airborne endotoxins: An association with occupational lung disease. Applied Industrial Hygiene, 4, 50–56.

    CAS  Google Scholar 

  • Madsen, A. M. (2006). Airborne endotoxin in different background environments and seasons. Annals of Agricultural and Environmental Medicine, 13, 81–86.

    CAS  Google Scholar 

  • Millner, P. D. (2009). Bioaerosols associated with animal production operations. Bioresource Technology, 100, 5379–5385.

    Google Scholar 

  • Milton, D. K., Gere, R. J., Feldman, H. A., & Greaves, I. A. (1990). Endotoxin measurement: Aerosol sampling and application of a new Limulus method. American Industrial Hygiene Association Journal, 51, 331–337.

    CAS  Google Scholar 

  • Milton, D. K., Johnson, D. K., & Park, J.-H. (1997). Environmental endotoxin measurement: Interference and sources of variation in the Limulus assay of house dust. American Industrial Hygiene Association Journal, 58, 861–867.

    CAS  Google Scholar 

  • Morita, T., Tanaka, S., Nakamura, T., & Iwanaga, S. (1981). A new (1 → 3)-β-d-glucan-mediated coagulation pathway found in Limulus amebocytes. FEBS Letters, 129, 319–321.

    Article  Google Scholar 

  • Novitsky, T. J., Schmidt-Gengenbach, J., & Remillar, J. F. (1986). Factors affecting the recovery of endotoxin adsorbed to container surfaces. Journal of Parenteral Science and Technology, 40, 284–286.

    CAS  Google Scholar 

  • Olenchock, S. A., Lewis, D. M., & Mull, J. C. (1989). Effects of different extraction protocols on endotoxin analysis of airborne grain dust. Scandinavian Journal of Work, Environment and Health, 15, 430–435.

    CAS  Google Scholar 

  • Portengen, L., Preller, L., Tielen, M., Doekes, G., & Heederik, D. (2005). Endotoxin exposure and atopic sensitization in adult pig farmers. The Journal of Allergy and Clinical Immunology, 115, 797–802.

    Article  CAS  Google Scholar 

  • Radon, K., Danuser, B., Iversen, M., Monso, E., Weber, C., Hartung, J., et al. (2002). Air contaminants in different European farming environments. Annals of Agricultural and Environmental Medicine, 9, 41–48.

    CAS  Google Scholar 

  • Rao, C. Y., Riggs, M. A., Chew, G. L., Muilenberg, M. L., Thorne, P. S., Van Sickle, D., et al. (2007). Characterization of airborne molds, endotoxins, and glucans in homes in New Orleans after hurricanes Katrina and Rita. Applied and Environmental Microbiology, 73, 1630–1634.

    Article  CAS  Google Scholar 

  • Roslansky, P. F., & Novitsky, T. J. (1991). Sensitivity of Limulus amebocyte lysate (LAL) to LAL-reactive glucans. Journal of Clinical Microbiology, 29, 2477–2483.

    CAS  Google Scholar 

  • Rylander, R. (2007). Endotoxin in the air: Good or bad for you? Clinical Pulmonary Medicine, 14, 140–147.

    Article  Google Scholar 

  • SAS Institute Inc. (2004). SAS/STAT software, Version 9.2. Cary, NC, USA.

  • Spaan, S., Doekes, G., Heederik, D., Thorne, P. S., & Wouters, I. M. (2008). Effect of extraction and assay media on analysis of airborne endotoxin. Applied and Environmental Microbiology, 74, 3804–3811.

    Article  CAS  Google Scholar 

  • Spaan, S., Heederik, D. J. J., Thorne, P. S., & Wouters, I. M. (2007). Optimization of airborne endotoxin exposure assessment: Effects of filter type, transport conditions, extraction solutions, and storage of samples and extracts. Applied and Environmental Microbiology, 73, 6134–6143.

    Article  CAS  Google Scholar 

  • Walters, M., Milton, D., Larsson, L., & Ford, T. (1994). Airborne environmental endotoxin: A cross-validation of sampling and analysis techniques. Applied and Environmental Microbiology, 60, 996–1005.

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Robert S. Dungan.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Dungan, R.S., Leytem, A.B. The effect of extraction, storage, and analysis techniques on the measurement of airborne endotoxin from a large dairy. Aerobiologia 25, 265–273 (2009). https://doi.org/10.1007/s10453-009-9131-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10453-009-9131-9

Keywords

Navigation