Volume self-calibration for 3D particle image velocimetry

  • Research Article
  • Published:
Experiments in Fluids Aims and scope Submit manuscript

Abstract

Planar self-calibration methods have become standard for stereo PIV to correct misalignments between laser light sheet and calibration plane. Computing cross-correlation between images from camera 1 and 2 taken at the same time, non-zero disparity vectors indicate rotational and translational misalignments relative to the coordinate system defined by a calibration plate. This approach works well for thin light sheets but fails for extended volumes recorded in 3D-PTV or tomographic PIV experiments. Here it is primarily necessary to correct calibration errors leading to triangulation errors in 3D-PTV or in degraded tomographic volume reconstruction. Tomographic PIV requires calibration accuracies of a fraction of a pixel throughout the complete volume, which is difficult to achieve experimentally. A new volumetric self-calibration technique has been developed based on the computation of the 3D position of matching particles by triangulation as in 3D-PTV. The residual triangulation error (‘disparity’) is then used to correct the mapping functions for all cameras. A statistical clustering method suitable for dense particle images has been implemented to find correct disparity map peaks from true particle matches. Disparity maps from multiple recordings are summed for better statistics. This self-calibration scheme has been validated using several tomographic PIV experiments improving the vector quality significantly. The relevance for other 3D velocimetry methods is discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  • Brücker Ch (1996) 3-D scanning-particle-image-velocimetry: technique and application to a spherical cap wake flow. Exp Fluids 56:157–179

    Google Scholar 

  • Calluaud D, David L (2004) Stereoscopic particle image velocimetry measurements of a flow around a surface-mounted block. Exp Fluids 36:33–61

    Article  Google Scholar 

  • Coudert S, Schon JP (2001) Back-projection algorithm with misalignment corrections for 2D3C stereoscopic PIV. Meas Sci Technol 12:1371–1381

    Article  Google Scholar 

  • Elsinga GE, Scarano F, Wieneke B, van Oudheusden BW (2006) Tomographic particle image velocimetry. Exp Fluids 41:933–947

    Article  Google Scholar 

  • Hartley R, Sturm P (1994) Triangulation. ARPA Image Understanding Workshop, Monterey, pp 957–966

    Google Scholar 

  • Hori T, Sakakibara J (2004) High speed scanning stereoscopic PIV for 3D vorticity measurement in liquids. Meas Sci Technol 15:1067–1078

    Article  Google Scholar 

  • Maas HG (1996) Contributions of digital photogrammatry to 3D PTV. In: Dracos T (ed) Three-dimensional velocity and vorticity measuring and image annalysis techniques. Kluwer, Dordrecht, pp 191–208

    Google Scholar 

  • Michaelis D, Poelma C, Scarano F, Westerweel J, Wieneke B (2006) A 3D time-resolved cylinder wake survey by Tomographic PIV. In: 12th international symposium on flow visualization, Göttingen, Germany, 10–14 September

  • Prasad A (2000) Stereoscopic particle image velocimetry. Exp Fluids 29:103–116

    Article  Google Scholar 

  • Scarano F, David L, Bsibsi M, Calluaud D (2005) S-PIV comparative assessment: image dewarping + misalignment correction and pinhole + geometric back projection. Exp Fluids 39:257–266

    Article  Google Scholar 

  • Soloff SM, Adrian RJ, Liu ZC (1997) Distortion compensation for generalized stereoscopic particle image velocimetry. Meas Sci Technol 8:1441–1454

    Article  Google Scholar 

  • Westerweel J, Scarano F (2005) A universal detection criterion for the median test. Exp Fluids 39–6, 1096

  • Wieneke B (2005) Stereo-PIV using self-calibration on particle images. Exp Fluids 39:267–280

    Article  Google Scholar 

  • Wieneke B, Taylor S (2006) Fat-sheet PIV with computation of full 3D-strain tensor using tomographic reconstruction. In: 13th international symposium on applications of laser techniques to fluid mechanics, Lisbon

  • Willert C (1997) Stereoscopic digital particle image velocimetry for application in wind tunnel flows. Meas Sci Technol 8:1465–1469

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to B. Wieneke.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wieneke, B. Volume self-calibration for 3D particle image velocimetry. Exp Fluids 45, 549–556 (2008). https://doi.org/10.1007/s00348-008-0521-5

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00348-008-0521-5

Keywords

Navigation