Abstract
Diffusion Magnetic Resonance Imaging (dMRI) is a widely-utilized method for assessment of microstructural properties in the central nervous system i.e., the brain and spinal cord (SC). In the SC, almost all previous human studies utilized Diffusion Tensor Imaging (DTI), which cannot accurately model areas where white matter (WM) pathways cross or diverge. While High Angular Diffusion Resolution Imaging (HARDI) can overcome some of these limitations, longer acquisition times critically limit its applicability to clinical human studies. In addition, previous human HARDI studies have used limited spatial resolution, with typically a few slices and voxel size ~1 × 1 × 5 mm3 being acquired in tens of minutes. Thus, we have optimized a novel fast HARDI protocol that allows collecting dMRI data at high angular and spatial resolutions in clinically-feasible time. Our data was acquired, using a 3T Siemens Prisma scanner, in less than 9 min. It has a total of 75 diffusion-weighted volumes and high spatial resolution of 0.67 × 0.67 × 3 mm3 (after interpolation in Fourier space) covering the cervical segments C4–C6. Our preliminary results demonstrate applicability of our technique in healthy individuals with good correspondence between low fractional anisotropy (FA) gray matter areas from the dMRI scans, and the same regions delineated on T2-weighted MR images with spatial resolution of 0.35 × 0.35 × 2.5 mm3. Our data also allows the detection of crossing fibers that were previously shown in vivo only in animal studies.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Tuch, D.S.: Q-ball imaging. Magn Reson Med 52, 1358–72 (2004).
Behrens, T.E.J., Woolrich, M.W., et al.: Characterization and propagation of uncertainty in diffusion-weighted MR imaging. Magn Reson Med 50, 1077–88 (2003).
Cohen-Adad, J., Descoteaux, M., Rossignol, S., et al.: Detection of multiple pathways in the spinal cord using q-ball imaging. Neuroimage 42, 739–749 (2008).
Cohen-Adad, J., El Mendili M.M., Lehéricy, S., et al.: Demyelination and degeneration in the injured human spinal cord detected with diffusion and magnetization transfer MRI. Neuroimage 55, 1024–1033 (2011).
Cohen-Adad, J., Benali, H., et al.: In vivo DTI of the healthy and injured cat spinal cord at high spatial and angular resolution. Neuroimage 40, 685–697 (2008).
Ellingson, B.M., Sulaiman, O., Kurpad, S.N.: High-resolution in vivo diffusion tensor imaging of the injured cat spinal cord using self-navigated, interleaved, variable-density spiral acquisition (SNAILS-DTI). Magn Reson Imaging 28, 1353–1360 (2010).
Zimolka, J., Piskořová, Z., et al.: HARDI dMRI imaging of cervical spinal cord. In: Proceedings of the 23rd conference Student EEICT. Brno University of Technology, Brno, pp 305–307 (2017).
Tustison, N.J., Cook, P.A., Gee, J.C.: N4ITK: improved N3 bias correction. IEEE Trans Med Imaging 29, 1310–1320 (2011).
De Leener, B., Lévy, S., et al.: SCT: Spinal Cord Toolbox, an open-source software for processing spinal cord MRI data. Neuroimage 145, 24–43 (2017).
De Leener, B., Cohen-Adad, J., Kadoury, S. Automatic Segmentation of the Spinal Cord and Spinal Canal Coupled with Vertebral Labeling. IEEE Trans Med Imaging 34, 1705–1718 (2015).
Andersson, J.L.R., Skare, S., Ashburner, J.: How to correct susceptibility distortions in spin-echo echo-planar images: Application to diffusion tensor imaging. Neuroimage 20, 870–888 (2003).
Jenkinson, M., Beckmann, C.F., et al.: Fsl. Neuroimage 62, 782–790 (2012).
Andersson, J.L.R., Sotiropoulos, S.N.: An integrated approach to correction for off-resonance effects and subject movement in diffusion MR imaging. Neuroimage 125, 1063–1078 (2016).
Martin, A.R., De Leener, B., et al.: A Novel MRI Biomarker of Spinal Cord White Matter Injury: T2*-Weighted White Matter to Gray Matter Signal Intensity Ratio. Am J Neuroradiol 38, 1266–1273 (2017).
Acknowledgements
We would like to express many thanks to Julien Cohen-Adad from Polytechnique Montréal in Canada for his help and insightful advice with optimal Spinal Cord Toolbox settings. We acknowledge the core facility Multimodal and Functional Imaging Laboratory, institution Masaryk University, CEITEC supported by the MEYS CR (LM2015062 Czech-BioImaging); special thanks to Veronika Fabíková and Petr Kudlička. This research was supported and funded by the Czech Health Research Council grants n. NV18-04-00159, NV16-30210A and NV17-29452A, and by the Ministry of Health of the Czech Republic project for conceptual development in research organizations, ref. 65269705 (University Hospital, Brno, Czech Republic). C.L. is partly supported by NIH grant P41 EB015894. Computational resources were supplied by the MEYS CR under the Projects CESNET (Project No. LM2015042) and CERIT-Scientific Cloud (Project No. LM2015085).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Labounek, R. et al. (2019). Fast In Vivo High-Resolution Diffusion MRI of the Human Cervical Spinal Cord Microstructure. In: Lhotska, L., Sukupova, L., Lacković, I., Ibbott, G.S. (eds) World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings, vol 68/1. Springer, Singapore. https://doi.org/10.1007/978-981-10-9035-6_1
Download citation
DOI: https://doi.org/10.1007/978-981-10-9035-6_1
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-9034-9
Online ISBN: 978-981-10-9035-6
eBook Packages: EngineeringEngineering (R0)