Abstract
In the evaluation of cancellous bone using ultrasonic backscatter, the amplitude of the backscatter signal is usually quite weak and the signal-to-noise ratio (SNR) is relatively low. This study used the m-sequence as the excitation to enhance the intensity and the anti-noise performance of the backscatter signal. The minimum peak sidelobe (MPS) filter was used to decode the received backscatter signal. The finite-difference time-domain (FDTD) simulation results show that the amplitude of the backscatter signal gets an enhancement of approximately 3.6 times with m-sequence than the monopulse excitation, and the decoded signal is approximately 93.9% identical to the ideal response of monopulse excitation. When the SNR decreased, the correlation coefficient between the monopulse signal and the ideal response decreased significantly, while the correlation of the m-sequence response changed little and remained steady, proving that the m-sequence signal gets a very good anti-noise performance. In vitro experiments were performed with bovine cancellous bones. In vitro results showed that the amplitude of the backscatter signal get an enhancement of approximately 3.8 times with m-sequence than the monopulse excitation, and the decoded signal was 94.6% identical to the ideal response of monopulse excitation. This study suggested that the ultrasonic backscatter of m-sequence excitation could be used for cancellous bone evaluation.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Wear KA (2008) Ultrasonic scattering from cancellous bone: a review. IEEE Trans Ultrason Ferroelectr Freq Control 55:1432–1441
Laugier P, Haïat G (2011) Bone quantitative ultrasound. Springer, New York
Liu C, Zhang R, Li Ying et al (2015) An ultrasonic backscatter instrument for cancellous bone evaluation in neonates. Engineering 1(3):336–343
Chiao RY, Hao X (2003) Coded excitation for diagnostic ultrasound: a system developer’s perspective. IEEE Ultrason Symp 2003:437–448
Zhang HL, Wu SJ, Ta DA et al (2014) Coded excitation of ultrasonic guided waves in long bone fracture assessment. Ultrasonics 54:1203–1209
Yang CC, Huang JF, Tseng SP (2004) Optical CDMA network codecs structured with M-sequence codes over waveguide-grating routers. IEEE Photonics Technol Lett 16(2):641–643
Dinan EH, Jabbari B (1998) Spreading codes for direct sequence CDMA and wideband CDMA cellular networks. IEEE Commun Mag 36:48–54
Trebacz H, Natali A (1999) Ultrasound velocity and attenuation in cancellous bone samples from lumbar vertebra and calcaneus. Osteoporos Int 9:99–105
Zeng YQ, He JQ, Liu QH (2001) The application of the perfectly matched layer in numerical modeling of wave propagation in poroelasticmedia. Geophysics 66:1258–1266
Acknowledgements
This work was supported by the NSFC (11327405, 11504057 and 11525416), Science and technology support program of Shanghai (13441901900), and China Postdoctoral Science Foundation (2015M571490).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Xu, F., Liu, C., Ta, D. (2018). M-Sequence Excitation of Ultrasonic Backscatter Signals for Cancellous Bone Evaluation. In: Vo Van, T., Nguyen Le, T., Nguyen Duc, T. (eds) 6th International Conference on the Development of Biomedical Engineering in Vietnam (BME6) . BME 2017. IFMBE Proceedings, vol 63. Springer, Singapore. https://doi.org/10.1007/978-981-10-4361-1_7
Download citation
DOI: https://doi.org/10.1007/978-981-10-4361-1_7
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-4360-4
Online ISBN: 978-981-10-4361-1
eBook Packages: EngineeringEngineering (R0)