Abstract
During the past decade endoscopic techniques have been increasingly used in surgical treatment with considerable benefit to patient care. In carrying out surgical procedures, the different methods of incision, dissection and coagulation are of special importance, and a full understanding of the principles governing their safe usage by the surgeon is essential. The endoscopic surgical approach has led to modifications and new developments of the operative ancillary technology. In addition to familiarization with the actual instruments, knowledge concerning the interaction of the applied technology with biological tissue is of decisive significance in ensuring a consistently favourable outcome after surgical intervention.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Baggish MS, Chong AP (1981) Carbon dioxide laser microsurgery of the uterine tube. Obstet Gynecol 58:111
Bodem F, Reidenbach H-D, Frühmorgen P, Matek W, Kaduk B (1980) Investigation on the hemostatic efficacy of the thermocoagulation of gastrointestinal hemorrhages by convective heat transfer via a miniature endoscopic hot gas probe. Biomed Tech (Berlin) 25:179–181
Boulnois J-L (1986) Photophysical processes in recent medical laser development: a review. Lasers Med Sci 1:47–66
Bruhat M, Mage C, Manhes M (1979) Use of the carbon-dioxide laser via laparoscopy. Proc. of 3rd Congress of the International Society for Laser Surgery, Laser Surgery III 275
Daniell J (1989) Fiberoptic laser laparoscopy. In: Sutton C (ed) Laparoscopic surgery, 3/3. Bailliere, London
Diamond M, De Cherney A, Lake Polan M (1986) Laparoscopic use of the argon laser in nonendometriotic reproductive pelvic surgery. J Reprod Med 31:1011
Freeman MA, Incropera FP (1970) Operational characteristics of a prototype arc plasma scalpel. Proc Annu Conf Med Biol 23:336
Frühmorgen P, Bodem F, Reidenbach H-D (1980) The state of the art of biomedical engineering in the operative endoscopic treatment of gastrointestinal bleeding. Hepatogas-troenterology 27:337–342
Keckstein J, Wolf A, Steiner R (1987) The use of contact laser probe in gynecological endoscopy. Proc. of 7 th Congress of International Society for Laser Surgery and Medicine, 267
Keckstein J, Finger A, Steiner R (1988) Laser application in contact and noncontact procedures; sapphire tips in comparison to “bare-fiber”, argon laser in comparison to Nd: Yag laser. Laser Med Surg. 4:158
Keckstein J, Hepp S, Schneider V, Sasse V, Steiner R (1990) The contact Nd: YAG laser: a new technique for conservation of the fallopian tube in unruptured ectopic pregnancy. Br J Obstet Gynaecol 97:352
Keckstein J, Tuttlies F, Wolf AS, Lauritzen C, Steiner R (1990) Lineare Salpingotomie zur Therapie der nicht rupturierten Tubargravidität — Tierexperimentelle Untersuchung, Vergleich von drei verschiedenen Lasersystemen. Zentralb Gyn 112:445
Keye W, Dixon J (1983) Photocoagulation of endometriosis by the argon laser through the laparoscope. Obstet Gynecol 62:383
Matek W, Frühmorgen P (1980) Elektro-Hydrothermo-Sonde. Dtsch Med Wochenschr 108:816–820
Nath G, Kreitmair A, Kiefhaber P, Moritz K (1978) Neue Infrarot-Koagulationsmethode. In: Rösch W (ed) Fortschritte in der Endoskopie. Perimed, Erlangen, pp 17–19
Proteil R, Auth D, Terrou F, Rubin C (1977) A miniaturized endoscopic heater probe: tests of efficacy in experimental acute gastric ulcer bleeding. Gastrointest Endosc 23:238
Reidenbach H-D (1983) Hochfrequenz- und Lasertechnik in der Medizin. Springer, Berlin Heidelberg New York
Reidenbach H-D (1990) Technologische Grundlagen der endoskopischen Blutstillung mit flexiblen Instrumenten. In: Buess G (ed) Endoskopie. Deutscher Ärzte, Köln, pp 105–124
Reidenbach H-D (1990) Laserphysikalische Grundlagen und Transmissionssysteme für Laserstrahlung. In: Lehmann, H-J, Reidenbach, H-D. (eds) Laser in der Medizin. TÜV Rheinland, Köln, pp 37–55
Reidenbach H-D (1990) Trennen und Fügen in der Medizin — aus der Sicht der Technik. Biomed Tech (Berlin) 35:1–9
Reidenbach H-D, Bodem F, Frühmorgen P, Schroeder G, Lex P, Kaduk B (1978) Eine neue Methode zur endoskopischen Hochfrequenzkoagulation von Schleimhautdefekten. Biomed. Tech 23:71–74
Reidenbach H-D, Buess G, Dollinger K, Kipfmüller K, Heintz A (1988) Biophysical-technical aspects of the endo-scopical-surgical preparation and hemostasis. Proceedings BME-Austria 88, Graz, June 9–11, pp 70–76
Rubin C, Auth D, Silverstein F, Protell R, Dennis M (1976) Preliminary study of a teflon-coated heater for endoscopic control of upper gastrointestinal bleeding in a standard ulcer model. Gastrointest Endosc 22:235
Semm K (1990) Operative Pelviskopie. In: Buess G (ed) Endoskopie. Deutscher Ärzte, Köln, pp 245–268
Sutton C (1986) Initial experience with carbon dioxide laser laparoscopy. Lasers Med Science 1:25
Wittmoser R (1984) Diathermic In: Buess G, Unz F, Pichlmaier H (eds) Endoskopische Techniken. Deutscher Ärzte, Köln, pp 174–178
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1992 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Reidenbach, HD., Buess, G. (1992). Ancillary Technology: Electrocautery, Thermocoagulation and Laser. In: Cuschieri, A., Buess, G., Périssat, J. (eds) Operative Manual of Endoscopic Surgery. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-22257-7_5
Download citation
DOI: https://doi.org/10.1007/978-3-662-22257-7_5
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-662-22259-1
Online ISBN: 978-3-662-22257-7
eBook Packages: Springer Book Archive