Abstract

In 1992, the first third generation scanner with more than a single row of detectors (Elscint CT Twin) was introduced on the market. The simple fact that it was now possible to scan two slices simultaneously gave rise to some guesswork as to how this might affect patient dose. Whereas some believed that the patient dose must double (because two slices were irradiated instead of one), others argued that the dose was rather halved (because the total mAs product was reduced by a factor two).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 74.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Brix G, Nagel HD, Stamm G, Veit R, Lechel G, Griebel J, Galanski M (2003) Radiation exposure in multislice versus single-slice spiral CT: results of a nationwide survey. Eur Radiol 13:1979–1991

    Article  PubMed  CAS  Google Scholar 

  • Cohnen M, Poll LW, Puettmann C, Ewen K, Saleh A, Mödder U (2001) Radiation exposure and image noise in single-slice and multislice CT of the body. AJR (submitted)

    Google Scholar 

  • Council of the European Union (1997) Council directive 97/43/ Euratom of 30 June 1997 on health protection against the dangers of ionizing radiation in relation to medical exposure, and repealing directive 84/466/Euratom. Document 397L0043. Official journal no L 180, 09/07/1997, pp 22–27

    Google Scholar 

  • Flohr T, Klingenbeck-Regn K, Ohnesorge B, Schaller S (2001) Multislice scanning with the Somatom Volume Zoom: an optimised design for volume scanning. In: Reiser MF, Takahashi M, Modic M, Bruening R (eds) Multislice CT. Springer, Berlin Heidelberg New York, pp 3–7

    Google Scholar 

  • Galanski M, Nagel HD, Stamm G (2001) CT-Expositionspraxis in der Bundesrepublik Deutschland — Ergebnisse einer bundesweiten Umfrage im Jahre 1999. Fortschr Rontgen-str 173:R1–R66

    Article  Google Scholar 

  • Giacomuzzi SM, Torbica P, Rieger M et al (2001) Untersuchung zur Strahlenexposition bei der Einzelschicht- und Mehrschicht-Spiral-CT (eine Phantomstudie). Fortschr Rontgenstr 173:643–649

    Article  CAS  Google Scholar 

  • Huda W, Mergo PJ (2001) How will the introduction of multislice CT affect patient doses? In: Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Malaga, Spain, pp 202–205

    Google Scholar 

  • McCollough CH, Zink FE (1999) Performance evaluation of a multislice CT system. Med Phys 26:2223–2230

    Article  PubMed  CAS  Google Scholar 

  • Nagel HD (ed.), Galanski M, Hidajat N, Maier W, Schmidt T (2002) Radiation exposure in computed tomography — fundamentals, influencing parameters, dose assessment, optimisation, scanner data, terminology. CTB Publications, Hamburg (contact: ctb-publications@gmx.de)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2004 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Nagel, HD. (2004). Radiation Dose Issues with MSCT. In: Reiser, M.F., Takahashi, M., Modic, M., Becker, C.R. (eds) Multislice CT. Diagnostic Imaging. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-05379-9_2

Download citation

  • DOI: https://doi.org/10.1007/978-3-662-05379-9_2

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-662-05381-2

  • Online ISBN: 978-3-662-05379-9

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics