Skip to main content

The direct intra-arterial method for ambulatory blood pressure recording: present status and future applications

  • Conference paper
Blood Pressure Measurements

Abstract

The indirect method for blood pressure recording devised by Riva-Rocci has not changed substantially since the first description. The technique is known to be inaccurate and slow-moving, and there are no satisfactory explanations for most of the observed and measured inaccuracies (6, 14). In contrast, the direct methods for measuring blood pressure have steadily increased in accuracy and sophistication, and it is recognised that these techniques are precise and rapid-moving. The direct techniques are the only available methods for accurate recording of blood pressure, and the Oxford technique developed by Scott and his colleagues (1) in the laboratories of Sir Georg Pickering is of particular importance because it remains the only way of obtaining accurate information on blood pressure variability in the ambulant individual subject. The technique has been shown to be safe (10), but it is invasive and this factor limits its application to a few centers engaged in research with the resources to ensure continued safety.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Bevan AT, Honour AJ, Scott FH (1969) Direct arterial pressure recording in unrestricted man. Clin Sci 36: 329–344

    PubMed  CAS  Google Scholar 

  2. Bock KD, Kreuzenbeck W (1966) Spontaneous blood pressure variations in hypertension: the effect of anti-hypertensive therapy and correlations with the incidence of complications. In: Gross F (ed) Antihypertensive therapy. Principles and Practice. Springer, Berlin Heidelberg, pp 224–228

    Google Scholar 

  3. Davies AB, Bala Subramanian V, Cashman PMM, Raftery EB (1983) Simultaneous recording of continuous arterial pressure, heart rate, and ST segment in ambulant patients with stable angina pectoris. Br Heart J 50: 85–91

    Article  PubMed  CAS  Google Scholar 

  4. Davies AB, Gould BA, Cashman PMM, Raftery EB (1984) Circadian rhythm of blood pressure in patients dependent on ventricular demand pacemakers. Br Heart J 52: 93–98

    Article  PubMed  CAS  Google Scholar 

  5. Gould BA, Mann S, Davies AB, Altman DG, Raftery EB (1981) Does Placebo Lower blood Pressure? Lancet II: 1377–1381

    Google Scholar 

  6. Gould BA (1982) An evaluation of indirect methods of ambulatory blood pressure recording. MD Thesis, University of London, pp 54–55

    Google Scholar 

  7. Littler WA, Honour Ai, Sleight P (1974) Direct arterial pressure, pulse rate, and electrocardiogram during micturation and defaecation in unrestricted man. Am Heart J 88: 205–210

    Article  PubMed  CAS  Google Scholar 

  8. Mann S, Millar Craig MW, Melville D, Bala Subramanian V, Raftery EB (1979) Physical activity and the circadian rhythm of blood pressure. Clin Sci 57 (Suppl 5): 375a - 377s

    Google Scholar 

  9. Mann S, Altman D, Raftery EB, Bannister R (1983) Circadian variation of blood pressure in autonomic failure. Circulation 68: 477–483

    Article  PubMed  CAS  Google Scholar 

  10. Mann S, Jones RI, Millar Craig MW, Wood C, Gould BA, Raftery EB (1984) The Safety of Ambulatory intra-arterial Pressure Monitoring: A Clinical Audit of 1000 Studies. Int J Cardiol 5: 585–597

    Article  PubMed  CAS  Google Scholar 

  11. Mann S, Millar Craig MW, Raftery EB (1985) Superiority of 24-hour-measurement of blood pressure over clinic values in determining prognosis in hypertension. Clin Exp Hypertens 7: 279–281

    Article  CAS  Google Scholar 

  12. Millar Craig MW, Bishop CN, Raftery EB (1978) Circadian variation of blood pressure. Lancet I: 795–797

    Google Scholar 

  13. Myers A, Dewar HA (1975) Circumstances attending 100 sudden deaths from coronary artery disease with Coroners Necropsies. Br Heart J 37: 1133–1143

    Article  PubMed  CAS  Google Scholar 

  14. Raftery EB, Ward AP (1968) The Indirect Method of Recording Blood Pressure. Cardiovasc Res 2: 210–281

    Article  PubMed  CAS  Google Scholar 

  15. Raftery EB, Millar Craig MW (1979) Blood Pressure Variation: Information derived from direct 24-hour Recordings. Proceedings International Conference on Blood Pressure Variation. University of Ghent. MTP Press, Lancaster, UK, pp 53–65

    Google Scholar 

  16. Rudolf EL, Unger T, Ganten D (1987) Atrial Natriuretic Peptide: a New Factor in Blood Pressure control. Hypertension 5: 255–272

    Article  Google Scholar 

  17. Sayers B McA, Cicchiello LR, Raftery EB, Mann S, Green H (1982) The assessment of continuous ambulatory blood pressure records. Med Inform 7: 93–108

    Article  CAS  Google Scholar 

  18. Smirk FH (1964) Observations on the mortality of 270 treated and 199 untreated grade 1 and 2 hypertensive patients followed in all instances for 5 years. N Z Med J 63: 413–443

    Google Scholar 

  19. Turton MB, Deegan T (1974) Circadian variations of plasma catecholamines, cortisol and imunoreactive insulin concentrations in supine subjects. Clin Chim Acta 55: 389–397

    Article  PubMed  CAS  Google Scholar 

  20. Wertheimer L, Bandul I, Amarsinghe S (1977) Blood Pressure in normal subjects. Proceedings Second International Symposium on Ambulatory Monitoring. Academic Press, London, pp 143–148

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1990 Dr. Dietrich Steinkopff Verlag GmbH & Co. KG, Darmstadt

About this paper

Cite this paper

Raftery, E.B. (1990). The direct intra-arterial method for ambulatory blood pressure recording: present status and future applications. In: Meyer-Sabellek, W., Gotzen, R., Anlauf, M., Steinfeld, L. (eds) Blood Pressure Measurements. Steinkopff. https://doi.org/10.1007/978-3-642-72423-7_13

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-72423-7_13

  • Publisher Name: Steinkopff

  • Print ISBN: 978-3-642-72425-1

  • Online ISBN: 978-3-642-72423-7

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics