Abstract
Self-expanding Nitinol (nickel-titanium alloy) stents are tubular, often mesh like structure, which are expanded inside a diseased artery segment to restore blood flow and keep the vessel open following angioplasty. The super-elastic and shape memory properties of Nitinol reduce the risk of damage to the stent, both during delivery into the body and due to accidents while in operation. However, as Nitinol stents are subjected to a long-term cyclic pulsating load due to the heart beating (typically 4×107 cycles/year) fatigue fracture may occur. One of the major design requirements in medical implants is the device lifetime or, in engineering terms, fatigue life. The objective of this paper is to optimize the stent design by reducing the strain amplitude and mean strain over the stent, which are generated by the cyclic pulsating load. An optimization based simulation methodology was developed in order to improve the fatigue endurance of the stent. The design optimization approach is based on the Response Surface Method (RSM), which is used in conjunction with Kriging interpolation and Sequential Quadratic Programming (SQP) algorithm.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Morgan, N.B.: Medical shape memory alloy applications– the market and its products. Materials Science & Engineering A 378, 19–23 (2004)
Pelton, A.R., Schroeder, V., Mitchell, M.R., Gong, X.Y., Barney, M., Robertson, S.W.: Fatigue and durability of Nitinol stents. Journal of the Mechanical Behavior of Biomedical Materials, 153–164 (2008)
Azaouzi, M., Lebaal, N.: Tool path optimization for single point incremental sheet forming using response surface method. Simulation Modeling Practice and Theory 24, 49–58 (2012)
Dean, A., Voss, D.: Design and Analysis of Experiments. Springer, New York (1999)
Kaymaz, I.: Application of Kriging method to structural reliability problems. Struct. Safety 27, 133–151 (2005)
Abaqus standard, Version 6.12, Dassault systems (2011), http://www.simulia.com
Auricchio, F., Taylor, R.L., Lubliner, J.: Shape memory alloys: macromodelling and nu-merical simulations of the superelastic behavior. Computer Methods in Applied Mechanics and Engineering 146, 281–312 (1997)
Lally, C., Prendergast, P.J.: An investigation into the applicability of a Mooney-Rivlin constitutive equation for modeling vascular tissue in cardiovascular stenting procedures. In: Proceedings of the International Congress on Computational Biomechanics, Zaragoza, Spain, pp. 542–550 (2003)
Holzapfel, G.A., Sommer, G., Regitnig, P.: Anisotropic Mechanical Properties of tissue components in Human Atherosclerotic plaques. Journal of Biomechanical Engineering 126, 657–665 (2004)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Azaouzi, M., Lebaal, N., Makradi, A., Belouettar, S. (2013). Optimization Based Simulation of Self-expanding Nitinol Stent. In: Haddar, M., Romdhane, L., Louati, J., Ben Amara, A. (eds) Design and Modeling of Mechanical Systems. Lecture Notes in Mechanical Engineering. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-37143-1_50
Download citation
DOI: https://doi.org/10.1007/978-3-642-37143-1_50
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-37142-4
Online ISBN: 978-3-642-37143-1
eBook Packages: EngineeringEngineering (R0)