Abstract
Pressure sensing by measuring the impedance of soft matter, like hydrogels and rubber, has so far posed the problems of low conductivity and hysteresis. Further modifications in the materials to enhance their properties are needed. A pressure sensor using a simple gelatin/agarose double network gel placed between two Ag/AgCl electrodes is presented. The impedance spectra from 100 Hz to 1 MHz were investigated and admittance calculated. Both response time and hysteresis were also investigated. All the experiments were made using an impedance analyzer from Zurich Instruments. Results showed that the lowest standard deviation is at 3.5 kHz. It was found that the admittance increases exponentially from 7.9 to approximately 11.7 mS with increasing the mechanical load at 3.5 kHz. The highest hysteresis of about ±7.6% was found to be at zero load. The measured response time of the gel impedance was approximately 0.5 s, which makes the double network gel feasible for real time pressure monitoring. Mechanical tests measuring the force on the gel due to deformation showed little influence of the gel structure on the impedance. Thus it was concluded that the change of the distance in between the electrodes is responsible for the impedance change of the gel. Calibrations will be necessary for practical applications, since the gel impedance changes as environmental conditions change. This sensor showed better results as compared to conductive rubber published in the literature. It can be concluded that agarose/gelatin gels provide a cheap and easy to fabricate pressure measuring device.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Pollack, G.H.: The cell as a biomaterial. J. Mater. Sci. Mater. Med. 13, 811–821 (2002)
Peppas, N.A., Hilt, Z., Khademhosseini, A., Langer, R.: Hydrogels in biology and medicine: from molecular principles to bionanotechnology. Adv. Mater. 18, 1345–1360 (2006)
Calvert, P.: Hydrogels for soft machines. Adv. Mater. 21, 743–756 (2009)
Peak, C.W., Wilker, J.J., Schmidt, G.: A review on tough and sticky hydrogels. Colloid Polym. Sci. 291, 2031–2047 (2013)
Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., Adler, H.-J.P.: Review on hydrogel-based pH sensors and microsensors. Sensors 8, 561–581 (2008)
Miao, Y., Zhang, K., Yuam, Y., Liu, B., Zhang, H., Liu, Y., Yao, J.: Agarose gel-coated LPG based on two sensing mechanisms for relative humidity measurement. Appl. Opt. 52(1), 90–95 (2013)
Sawahata, K., Gong, J.P., Osada, Y.: Soft and wet touch-sensing system made of hydrogel. Macromol. Rapid Commun. 16, 713–716 (1995)
Osada, Y., Gong, J.-P.: Soft and wet materials: polymer gels. Adv. Mater. 10(11), 827–837 (1998)
González-Correa, C.A., Brown, B.H., Smallwood, R.H., Walker, D.C., Bardhan, K.D.: Electrical bioimpedance readings increase with higher pressure applied to the measuring probe. Physiol. Meas. 26, 39–47 (2005)
Dodde, R.E., Bull, J.L., Shih, A.J.: Bioimpedance of soft tissue under compression. Physiol. Meas. 33, 1095–1109 (2012)
Belmont, B., Dodde, R.E., Shih, A.J.: Impedance of tissue-mimicking phantom material under compression. J. Electr. Bioimp. 4, 2–12 (2013)
Gu, W.Y., Yao, H., Vega, A.L., Flagler, D.: Diffusivity of ions in agarose gels and intervertebral disc: effect of porosity. Ann. Biomed. Engin. 32(12), 1710–1717 (2004)
Gu, W.Y., Justiz, M.A., Yao, H.: Electrical conductivity of limbar annulus fibrosis: effects of porosity and fixed charge density. Spine 27(21), 2390–2395 (2002)
Somboon, N., Karilla, T.T., Kaewmanee, T., Karilla, S.J.: Properties of gels from mixed agar and fish gelatin. IFRJ 21(2), 485–492 (2014)
Mei, H., Zhang, C., Wang, R., Feng, J., Zhang, T.: Impedance characteristics of surface pressure-sensitive carbon black/silicone rubber composites. Sens. Actuator A 233, 118–124 (2015)
Khalili, N., Naguib, H.E., Kwon, R.H.: A constriction resistance model of conjugated polymer based piezoresistive sensors for electronic skin applications. Soft Matter 12, 4180–4189 (2016)
Acknowledgments
We would like to thank the State University of Santa Catarina (UDESC), CAPES and FAPESC (2454/2011-6) for the financial support. We also would like to thank the staff of the chemistry department and the team of the Polymer laboratory of UDESC for their professional and practical help.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Brunnquell, S., Sirtoli, V., Bertemes-Filho, P. (2020). Gel Impedance Used as a Pressure Sensor: Preliminary Results. In: González Díaz, C., et al. VIII Latin American Conference on Biomedical Engineering and XLII National Conference on Biomedical Engineering. CLAIB 2019. IFMBE Proceedings, vol 75. Springer, Cham. https://doi.org/10.1007/978-3-030-30648-9_190
Download citation
DOI: https://doi.org/10.1007/978-3-030-30648-9_190
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-30647-2
Online ISBN: 978-3-030-30648-9
eBook Packages: EngineeringEngineering (R0)