Abstract
Over the last three decades, fluorescence has become the most widely used detection method in biomedical science. Fluorescence measurements are utilized in basic and translational research, method development, medical laboratory tests, clinical trials and epidemiologic studies. This renders the availability of objective methods to assess the quality of data obtained by these measurements very critical for research scientists, clinical laboratory personnel, and regulatory reviewers as is addressed in this chapter.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Mansfield E, O'Leary TJ, Gutman SI (2005) J Mol Diagn 7:2
Jezequel P, Pichon J, Magrangeas F, Minvielle S, Millour M, Ricolleau G, Malvaux S (2004) Ann Biol Clin (Paris) 62:361
Clinical and Laboratory Standards Institute (2004) Fluorescence calibration and quantitative measurements of fluorescence intensity; approved guideline I/LA24-A (ISBN 1-56238-543-7). CLSI, Pennsylvania
Tholen D (2006) Med Lab Obs 38:38, 40
FDA Modernization Act of 1997: Guidance for the recognition and use of consensus standards; availability. Federal Register: February 25, 1998, Vol. 63, No. 37. Notices, pp 9561
Kaplan LA (1999) Scand J Clin Lab Invest 59:479
DeRose P, Cramer G, Gaigalas A, Panne U, Resche-Genger U. This volume
Garsha K (2008) Quantification in fluorescence microscopy. This volume
Shi L, Goodsaid FM, Frueh FW, Tong W (2008) Microarray technology: unresolved issues and future challenges from a regulatory perspective. This volume
DeRose P, Wang L, Gaigalas A, Kramer G, Resch-Genger U, Panne U (2008) Need for and metrological approaches towards standardization of fluorescence measurements from the view of national metrological institutes. This volume
Resch-Genger U, Pfeifer D, Hoffmann K, Flachenecker G, Hoffmann A, Monte C (2008) Linking fluorometry to radiometry with physical and chemical transfer standards: instrument characterization and traceable fluorescence measurements. This volume
Henderson LO, Marti GE, Gaigalas A, Hannon WH, Vogt RF (1998) Cytometry 33:97
Coder DM, Redelman D, Vogt RF (1994) Cytometry 18:75
Muirhead KA, Schmitt TC, Muirhead AR (1983) Cytometry 3:251
Schwartz A, Repollet EF, Vogt RF, Gratama JW (1996) Cytometry 26:22
Schwartz A, Wang L, Early E, Gaigalas A, Zhang Y, Marti GE, Vogt RF (2002) J Res Natl Inst Stand Technol 107:83
Vogt RF, Cross GD, Henderson LO, Phillips DL (1989) Cytometry 10:294
Brown MC, Hoffman RA, Kirchanski SJ (1986) Ann NY Acad Sci 468:93
Schwartz A, Fernandez-Repollet E (1993) Ann NY Acad Sci 677:28
Schwartz A, Marti GE, Poon R, Gratama JW, Fernandez-Repollet E (1998) Cytometry 33:106
Gaigalas AK, Li L, Henderson O, Vogt R, Barr J, Marti G, Weaver J, Schwartz A (2001) J Res Natl Inst Stand Technol 106:381
Wang L, Gaigalas AK, Abbassi F, Marti GE, Vogt RF, Schwartz A (2002) J Res Natl Inst Stand Technol 107:339
Galgalas AK, Wang L, Schwartz A, Marti GE, Vogt RF (2003) J Res Natl Inst Stand Technol 110:101
Schwartz A, Gaigalas AK, Wang L, Marti GE, Vogt RF, Fernandez-Repollet E (2004) Cytom B, Clin Cytom 57:1
Wang L, Abbasi F, Gaigalas A, Hoffman RA, Flagler D, Marti GE (2007) Cytometry B, Clinical Cytom 72:442–449
Vogt RF, Marti GE, Schwartz A (1995) Quantitative calibration of fluorochrome intensity for clinical and research applications of leukocyte immunophenotyping by flow cytometry. In: Tyrer HW (ed) Critical issues in biotechnology and bioengineering, vol. 1. Ablex, New Jersey, p 147
Gratama JW, D'hautcourt JL, Mandy F, Rothe G, Barnett D, Janossy G, Papa S, Schmitz G, Lenkei R (1998) Cytometry 33:166
Serke S, van Lessen A, Huhn D (1998) Cytometry 33:179
Lenkei R, Gratama JW, Rothe G, Schmitz G, D'hautcourt JL, Arekrans A, Mandy F, Marti G (1998) Cytometry 33:188
Davis KA, Abrams B, Iyer SB, Hoffman RA, Bishop JE (1998) Cytometry 33:197
International Organization for Standardization (1993) International vocabulary of basic and general terms in metrology. ISO, Geneva
Clinical and Laboratory Standards Institute (2004) Protocols for determination of limits of detection and limits of quantitation; approved guideline EP17-A. CLSI, Pennsylvania
Wood JC, Hoffman RA (1998) Cytometry 33:256
Wood JC (1998) Cytometry 33:260
Chase ES, Hoffman RA (1998) Cytometry 33:267
Poncelet P, Carayon P (1985) J Immunol Methods 85:65
Bikoue A, Janossy G.1, Barnett D (2002) J Immunol Methods 266:19
Chatelier RC, Ashcroft RG, Lloyd CJ (1986) EMBO J 5:1181
Hultin LE, Matud JL, Giorgi JV (1998) Cytometry 33:123
Iyer SB, Hultin LE, Zawadzki JA, Davis KA, Giorgi JV (1998) Cytometry 33:206
Schmitz JL, Czerniewski MA, Edinger M, Plaeger S, Gelman R, Wilkening CL, Zawadzki JA, Wormsley SB (2000) Cytometry 42:174
Wang L, Abbasi F, Gaigalas AK, Vogt RF, Marti GE (2006) Cytometry 70B:410
Kay S, Herishanu Y, Pick M, Rogowski O, Baron S, Naparstek E, Polliack A, Deutsch VR (2005) Cytometry 70B:218
Davis BH (2002) Cytometry [Suppl] 11:49
Mittag A, Lenz D Gerstner AO, Tarnok A (2006) Cytometry 69A:691
Ortyn WE, Perry DJ, Venkatachalam V, Liang L, Hall BE, Frost K, Basiji DA (2007) Cytometry A 71(4):215–231
Xiao Y, Barker PE (2008) Cellular bioimaging in fluorescent cancer biomarker evaluation: validation, technologies and standards development. This volume
Purvis N, Stelzer G (1998) Cytometry 33:156
Earley MC, Vogt RF, Shapiro HM, Mandy FF, Kellar KL, Bellisario R, Pass KA, Marti GE, Stewart CC, Hannon WH (2002) Cytometry 50:239
Seydack M (2008) Particle-based assays: applications and unresolved issues. This volume
Keeney M, Barnett D, Gratama JW (2004) J Biol Regul Homeost Agents 18:305
Strom CM, Janeszco R, Quan F, Wang S, Buller A, McGinniss M, Sun W (2006) J Mol Diagn 8:371
Strom CM, Janeszco R, Quan F, Wang SB, Buller A, McGinniss M, Sun W (2006) J Mol Diagn 8:371
Wion E, Brantley M, Stevens J, Gallinger S, Peng H, Glass M, Hagopian W (2003) Ann NY Acad Sci 1005:400
Marti GE, Gaigalas A, Vogt RF (2000) Cytometry 42:263
Baker SC, Bauer SR, Beyer RP, Brenton JD, Bromley B, Burrill J, Causton H, and the External RNA Controls Consortium (2005) Nature Methods 2:731
Holden M, Wang L (2008) Quantitative real-time PCR: fluorescent probe options and issues. This volume
Weksberg R, Hughes S, Moldovan L, Bassett AS, Chow EW, Squire JA (2005) BMC Genomics 6:180
Author information
Authors and Affiliations
Corresponding author
Editor information
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Vogt Jr., R.F., Marti, G.E., Zenger, V. (2008). Quantitative Fluorescence Calibration: a Tool for Assessing the Quality of Data Obtained by Fluorescence Measurements. In: Resch-Genger, U. (eds) Standardization and Quality Assurance in Fluorescence Measurements I. Springer Series on Fluorescence, vol 5. Springer, Berlin, Heidelberg. https://doi.org/10.1007/4243_2008_055
Download citation
DOI: https://doi.org/10.1007/4243_2008_055
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-75206-6
Online ISBN: 978-3-540-75207-3
eBook Packages: Chemistry and Materials ScienceChemistry and Material Science (R0)